20
1.3.
Electric wiring diagram
Options for protecting devices and cable specification:
Model
PRO 6
PRO 8
PRO 9
PRO 13
Breaker
Rated current (A)
8
9,5
11,5
15
Rated residual
action current (mA)
30
30
30
30
Fuse (A)
8
9,5
11,5
15
Power cord (mm
2
)
3 x 1,5
3 x 1,5
3 x 2,5
3 x 2,5
Signal cable (mm
2
)
3 x 0,5
3 x 0,5
3 x 0,5
3 x 0,5
* Above date is subject to modification without notice.
The above data is adapted to power cord ≤ 10m. If power cord is
>
10m, the wire diameter must be increased.
The signal cable can be extended to 50m at most.
1.4.
Installation requirement
The heat pump must be installed by a professional team. The users are not qualified to install by themselves,
otherwise the heat pump might be damaged and risky for users’ safety.
In order to guarantee the heating efficiency, the water pipe length should be ≤10m between the pool and the
heat pump.
1.5.
Instructions for installation
-
Location en free space: the heat pump should be installed in a place with enough free space and
enough ventilation around the machine.