background image

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT.  MULTIPLE POWER SOURCES MAY BE PRESENT.  FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

26

WIRING DIAGRAMS

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

TO +VDC

TO

MICRO

TO

R

GND (4)

+

 VDC (1)

RX (2

)

TX (3

)

CIRCULATOR

INDOOR

A

IR

B

LWR

RD

GY

BL

BK

HUMIDIFIER

GND

PROTECTION DEVICE

HEAT OFF

DELAY

B

URNER COMPARTMENT

24 V
3 A

BL

G

P

OWER SUPPLY WITH

L

INE

RD

12

TO

C

2

B

K

R

D

UNUSED

4

IGNITER

FLAME SENSOR

INTEGRATED CONTROL MODULE

BR

YL

TE

RMINAL

HI

BL

OR OR ANGE

MVH (14)

PM

ECM

 MTR

H

ARNESS

NO

24 VAC

H

I VOLTAGE FIELD

115kBTU MODELS

D

IP SW

IT

C

H

ES

PS1 (2)

3

YL YELLO W

CIRCULATOR

BK

BR BROW N

4

B

K

 OVERCURRENT

24V HUM.

0140F00606        REV. A

IGNITER

1

15 VAC/ 1

BLOWER COMPARTMENT

BK

PM

1

W H  W HITE

BK

FUSE

15

EAC

C

2

BL BLUE

6

115 VAC

INDUCTOR COIL

W H

YL

GND

5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST
   RECENT, DEPRESS SWITCH FOR  MORE THAN 2 SECONDS WHILE
   IN STANDBY (NO THERMOSTAT INPUTS)

Ø /60 HZ  POW ER SUP PLY  W ITH

ADJUST

TO 115VAC/  1

BK BLACK

DEHUM

5

HEAT

LINE

IN

T

E

G

R

A

T

E

D

 CO

NTRO

L

 M

O

DU

L

E

GND

24V HUM.

2

WH

BK

MVC (8)

2

NEUTRAL

RD

W H

DOOR

LOW FIRE PRESS.
SWITCH

4

3

2

C

H

A

S

S

IS

 GR

OU

N

D

W H

LOW  VOLTAGE (24 V)

HUM

DEHUM

2

HI VOLTAGE (115 V)

PSO (7)

W H

2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE
   USED WHEN SERVICING.

ONLY

C

AIR CLEANER

HIGH FIRE
PRESS. SWTICH

INDOOR

HUMIDIFIER

PK PINK

WH

9

IND LO

14

Y2

40 VA

3

HU

M

YL

JUNCTION

BLWR

PU   PURPLE

1

CIRCULATOR
BLOW ER

R

1

JUNCTION BOX

SW ITCH (TEMP.)

NEUTRAL

115kBTU MODELS

BLOWER
COMPARTMENT
DOOR SWITCH
(OPEN WHEN
 DOOR OPEN)

C

LINE

YL

NEUTRAL

4

NEUTRAL

11

C

FS

2

PLUG C ONNECTION

EAC

DISCONNECT

PU

3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE
   FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH
   WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT
   LEAST 105°C. USE COPPER CONDUCTORS ONLY.

RD

INTEG RAT ED CONTROL

PROT. D EVICE

8

W H

ONLY

24 V THERMOSTAT CONNECTIONS

W1

W1

       INTERNAL  TO

70kBTU,90kBTU,

NO

EQUIPMENT GN D

MVL (13)

O

2ND STG DLY

W H

RD

YL

R

BL

2

5

GND (5)

BK

IND HI

IGN

PK

HLO (10)

70kBTU,90kBTU,

NOTES:

PU

AIR

Y1

Y1

GY GRAY

ELECTRONIC

RD RED

Y2

RD

NEUTRAL

1

HLI (1)

W H

SWITCH

NO

WH

TRANSFORMER

13

1

OR

3

OVERCURRENT PROTE CTION DEVICE

T-STAT

5

BR

BK

GN

3

LOW  VOLTAG E  FIE LD

W2

DELAY

7

FIELD GND

FIELD SPLICE

SW ITC H (PRESS.)

1

C

W2

W H

NEUTRAL

BLWR

JU
NC

T

ION
 B
O

X

3

GND

FS

1

4

BK

GAS
VALVE

24
V T

H

ERM

O

STA

T

 C

O

NN

ECTI

O

N

S

PU

INDUCTOR COIL

TH (4)

C

HI

1

2

4

V HUM

.

G

YL

C

TR (11)

YL

GR

GN GREEN

HOT SURFACE

PS2 (12)

1

IN

T

E

G

R

AT
ED
 C
O

NT
R

O

L

 M
O

D

U

L

E

COLOR  CODES:

4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO
   N.E.C. AND LOCAL CODES.

YL

DIAGNOSTIC

LED'S

RD

O

3

DE

HU

M

10

OR

NO

NEUTRAL

SEE
NOTE 5

WH

COOL

ID

TO
MICRO

PU

AUTO RESET
AUXILIARY
LIMIT CONTROL

YL

1. SET HEAT ANTICIPATOR ON RO OM THERMOSTAT AT 0.7 AMPS.

FUSE 3 A

2

*MVC8***AA Models

Summary of Contents for ADVC8

Page 1: ...to improper service procedures performed by an unqualified person ADVC8 AMVC8 GMVC8 80 Gas Furnace Units Refer to Service Manual RS6200004 for installation operation and troubleshooting information Al...

Page 2: ...ge personal injury or death Goodman will not be responsible for any injury or property damage arising from improper service or service procedures If you install or perform service on this unit you ass...

Page 3: ...uld questions arise contact your local EPA office WARNING WARNING Do not connect or use any device that is not design certified by Goodman for use with this unit Serious property damage personal injur...

Page 4: ...ower door is not in place Keep the blower access doors in place except for inspection and maintenance These furnaces are also equipped with a self diagnosing elec tronic control module In the event a...

Page 5: ...ONVERSIONKITREQUIR ED Tableddataisbaseduponthefurnaceinputbeingreducedforaltitudesabovesealevel U S 4 per1 000feet Canada10 deratefor2 000 4 000feet ELEVA TIONA BOVESEA LEVEL FEET INPUTPERBURN ER 22 5...

Page 6: ...Door Interlock Switch Transformer Circulator Blower 1 2 3 4 5 6 7 8 9 Inductor 1 Tubular Heat Exchanger 2 Pressure Switch 3 Flue Pipe Connection 4 Induced Draft Blower 5 Gas Line Entrance 6 Gas Valve...

Page 7: ...r Blower Inductor Pressure Switch 2 Gas Line Entrance Alternate Tubular Heat Exchanger 1 1 Tubular Heat Exchanger 2 Pressure Switch 3 Flue Pipe Connection 4 Induced Draft Blower 5 Gas Line Entrance 6...

Page 8: ...8_____X Alt Gas Inlet High Voltage Inlet Low Voltage Alt Gas Inlet Alt High Voltage Alt LowVoltage MODELS A B AMVC80704BX GMVC80704BX 17 1 2 16 AMVC80905CX AMVC81155CX GMVC80905CX GMVC81155CX 21 19 1...

Page 9: ...S 33 3 8 A B 28 High Voltage Electrical Low Voltage Electrical Gas Inlet MODEL A B NON COMBUSTIBLE FLOOR BASE ADVC80703BX 17 1 2 16 SBT17 ADVC80905CX ADVC81155CX 21 19 1 2 SBT21 All dimensions are in...

Page 10: ...0 3 B X 1 A D V C 8 0 9 0 5 C X 1 A D V C 8 1 1 5 5 C X 1 A U X I L I A R Y L I M I T S W I T C H E S MODEL TRIP POINT ID BLOWER PRESSURE SWITCH LOW STAGE TRIP POINT ID BLOWER PRESSURE SWITCH HIGH STA...

Page 11: ...CAUF equivalent All CHPF coils in B C D heights have an insulated Z bracket for use with one size smaller furnace All proper coil combinations are subject to being ARI rated with a matched outdoor un...

Page 12: ...mine filter area requirement NOTE Filters can also be installed elsewhere in the duct system such as a central return FURNACE INPUT FILTER SIZE TYPE 45M 160 in2 permanent 70M 241 in2 permanent 90M 320...

Page 13: ...owing downflow top return filter sizes depending on cabinet size Refer to Minimum Filter Area tables to determine filter area requirement NOTE Filters can also be installed elsewhere in the duct syste...

Page 14: ...ted External Static w c 10 50 10 50 10 50 Temperature Rise F 20 50 20 50 25 55 High Stage Pressure Switch Trip Point w c 0 65 0 60 0 60 Low Stage Pressure Switch Trip Point w c 0 30 0 30 0 30 Blower W...

Page 15: ...0 50 25 55 High S tage P res s ure S witc h Trip P oint w c 0 65 0 60 0 60 Low S tage P res s ure S witc h Trip P oint w c 0 30 0 30 0 30 B lower W heel D x W 10 x 8 10 x 10 10 x 10 B lower Hors epowe...

Page 16: ...80 Rated External Static w c 10 50 10 50 10 50 Temperature Rise F 30 60 35 65 35 65 High Stage Pressure Switch Trip Point w c 0 55 0 55 0 55 Low Stage Pressure Switch Trip Point w c 0 30 0 30 0 30 Bl...

Page 17: ...g Speed Tap Adjust Tap Low Stage CFM High Stage CFM Rise F Minus 790 1125 46 Minus 945 1350 49 Normal 875 1250 41 Normal 1050 1500 44 Plus 960 1375 38 Plus 1155 1650 40 Minus 850 1215 43 Minus 1010 14...

Page 18: ...Minus 540 Minus 720 Minus 720 Normal 600 Normal 800 Normal 800 Plus 660 Plus 880 Plus 880 Minus 720 Minus 990 Minus 990 Normal 800 Normal 1100 Normal 1100 Plus 880 Plus 1210 Plus 1210 Minus 990 Minus...

Page 19: ...w c and 0 8 w c is tabulated for cooling purposes only 6 Motor CFM maximum ADVC8 Continuous Fan Speed Chart AMVC8 GMVC8 Continuous Fan Speed Chart Model Furnace Maximum CFM Continuous Fan Speed 1 2 A...

Page 20: ...e CFM Rise F Heating Speed Tap Adjust Tap Low Stage CFM High Stage CFM Rise F Minus 660 945 55 Minus 850 1215 55 Normal 735 1050 49 Normal 945 1350 49 Plus 810 1155 45 Plus 1040 1485 45 Minus 725 1035...

Page 21: ...ng Speed Tap Adjust Tap CFM 1 Minus 540 Minus 720 Minus 765 Normal 600 Normal 800 Normal 850 Plus 660 Plus 880 Plus 935 Minus 720 Minus 990 Minus 1035 Normal 800 Normal 1100 Normal 1150 Plus 880 Plus...

Page 22: ...ximum CFM capaibility is 1760 CFM the continuous fan speed will be 0 30 X 1760 CFM 530 CFM Example If the furnace maximum CFM capaibility is 1760 CFM the continuous fan speed will be 0 30 X 1760 CFM 5...

Page 23: ...FF ramping profiles These profiles may be used to enhance cooling performance and increase comfort level The ramping profiles are selected using DIP switches 5 and 6 Refer to the following figure for...

Page 24: ...shown on rating plate 5 Do not operate above 0 5 w c ESP in heating mode Operating between 0 5 w c and 0 8 w c is tabulated for cooling purposes only 6 Motor CFM maximum 100 CFM OFF OFF Profile C ramp...

Page 25: ...30 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPU...

Page 26: ...IFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING ONLY C AIR CLEANER HIGH FIRE PRESS SWTICH INDOOR HUMIDIFIER PK PINK WH 9 IND LO 14 Y2 40 VA 3 HUM YL JUNCTION BLWR PU PURPLE 1 CIRCULATOR BLOW ER R...

Page 27: ...NTROLS HUM YL JUNCTION BLWR PU PURPLE 1 CIRCULATOR BLOWER R 1 GND JUNCTION BOX SWITCH TEMP NEUTRAL 115kBTU MODELS BLOWER COMPARTMENT DOOR SWITCH OPEN WHEN DOOR OPEN C LINE BK YL NEUTRAL 4 NEUTRAL POLA...

Page 28: ...0 AUTOMATIC IGNITION SYSTEM 24VAC 60Hz 0 8 A MAX 15 12 GND 13 9 G TX 2 O G 1 59 4715 REV F Y2 7 W1 3 W2 C IND LO 2 RX IND HI Y 1 Y1 O 1 G O DEHUM R R IND N HUM ST5 ST4 HUM C FS Y 2 1 DE HUM Y2 10 W 1...

Page 29: ...ference only Not all wiring is as shown above Refer to the appropriate wiring diagram for the unit being serviced Wiring is subject to change Always refer to the wiring diagram on the unit for the mos...