Comfortflame CGDV32NR (PR)-3 Installation Manual Download Page 1

FIREPLACE INSTALLATION

Figure 26 - Blower Model BK

Magnetic 

Strips

Exhaust 

Port 

Screw

Green 

Ground 

Wire

Spade 

Terminals

Side View

Lower Firebox 

Cavity

Blower 

Location

CHECK GAS TYPE

Use proper gas type for 

fireplace

 unit you are 

installing. If your gas supply is not correct, do 

not install 

fireplace.

 See retailer where you 

purchased 

firepla

ce for proper 

fireplace

 ac-

cording to your gas type or to purchase gas 

conversion kit (see 

Accessories

, page 37).

I

NSTALLING OPTIONAL BLOWER

ACCESSORY

NOTICE: If installing blower in 

an  existing 

fireplace

  with  gas 

connections,

 shut off gas 

sup

-

ply

 and 

disconnect

 heater from 

gas 

supply

Contact

 a 

qualified 

service person to do this.

 WARNING: If there is a 

dupl

ex 

el

ectr

i

ca

l  outlet  installed  in  the 

right  side  of  the  bottom  of  the 

re

place

 base area

,

 be sure that 

the el

ectr

i

ca

pow

er to the outlet is 

turned off before 

p

ro

cee

ding with 

blower installation. Failure to do 

this 

may

 result in serious injur

y

.

Model BK Installation

Follow  all  instructions  provided  in  blower 

accessory kit.
1.  Attach power cord to blower  motor by 

firmly

 pushing two female terminals at end 

of power cord onto two spade terminals 

on blower motor (see Figure 26).

2.  Attach green ground wire from power cord 

to blower housing using screw provided 

(see Figure 26). Tighten screws securely.

3.   Place blower against lower rear wall of 

firebox

 outer wrapper with exhaust port 

directed upward. Blower will 

fit

 inside back 

opening and be held in position against 

back wall by magnets (see Figure 26).

Summary of Contents for CGDV32NR (PR)-3

Page 1: ...ed service person to do this WARNING Ifthereisaduplex electrical outlet installed in the right side of the bottom of the fireplace base area be sure that theelectricalpowertotheoutletis turnedoffbeforeproceedingwith blower installation Failure to do this may result in serious injury Model BK Installation Follow all instructions provided in blower accessory kit 1 Attach power cord to blower motor by...

Page 2: ...Decal 12 in Front of Blower Speed Control Control Shaft Locknut Control Knob Switch Bracket Blower Plug In Duplex Outlet Located underneath firebox floor against lower right outside wall Model BKT Installation Note When installing BKT thermostati cally controlled blower you must first secure thermal switch bracket to blower if it has not already been factory installed 1 Place green ground wire with r...

Page 3: ...h Bracket Power Cord Air Flow Direction Magnetic Strips Figure 30 Blower Wiring Diagram for Thermostat Controlled Models Blower Wiring Diagram CAUTION Label all wires prior to disconnection when servicingcontrols Wiringerrors can cause improper and dan gerous operation Verify proper operation after servicing Blue Variable Fan Switch Fan Switch N O Green White On 110 115 V A C Blower Motor Black Of...

Page 4: ...re to between 11 and 14 of water If you do not reduce incoming gas pressure Figure 31 External Regulator with Vent Pointing Down Propane LP Only Propane LP Supply Tank External Regulator with Vent Pointing Down fireplace regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 31 Pointing the vent down protects it from freezing rain or sleet CAUTION Use...

Page 5: ...gshow a leak Correct all leaks at once PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnectfireplaceanditsindividualequip ment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig 3 5 kPa will damage fireplace gas regulator 2 Cap off open end of gas pipe where equip ment shutoff valve was connected 3 Pressurize supply piping syste...

Page 6: ...ee Figure 35 or Figure 36 Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak Correct all leaks at once 5 Light fireplace see Operation page 26 Check all other internal joints for leaks 6 Turn off fireplace see To Turn Off Gas to Appliance page 27 INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2 1 Connect one terminal of 25 ft wire for wall switch to TPTH terminal on valve Co...

Page 7: ...see Figure 40 2 Attach terminal wires to battery Place battery into battery housing 3 Replace battery cover onto remote control unit Figure 40 Installing Battery in Hand Held Remote Control Unit 9 Volt Battery Battery Housing Battery Cover Terminal Wires Remote Control Unit REMOVING REPLACING GLASS DOOR CAUTION Do not operate thisfireplacewithabrokenglass door panel or without the glass door panel ...

Page 8: ...2 Removing Replacing Glass Door Lock Unlock Glass Frame Assembly Screw Hinge Latch INSTALLING OPTIONAL BRICK LINER MODEL BL32D WARNING If fireplace has been running turn off and un plug fireplace Let cool before installing brick liner This brick liner kit is optional You may pur chase brick liner from your local retailer or see page 37 CAUTION Always handle brick panels with two hands Do not force b...

Page 9: ... Do not modify logs Only use logs supplied with fireplace Open louvers remove screen unlock door latches and open glass door See steps 1 and 2 of Removing Glass Door page 24 Install logs according to instructions for fireplace model numbers 1 Place log 1 rear log on top of grate Make sure notches in bottom of log fit over grate see Figure 45 2 Rest log 2 large front log on pins on front part of grate...

Page 10: ...AD BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a fire or explosion may result causing property damage per sonal injury or loss of life A This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some ...