Inside
Tu
Day
Upstairs
Auto
Downstairs
Airflow %
HEAT
Schedule
AUTO
FAN
MENU
MODE
Heat
Set To
SYSTEM
AM
365
Comfort
UP/DOWN
Keys.
SYSTEM MODE
Key
OFF, HEAT, COOL or AUTO
Displays the downstairs
(Inside) or upstairs (Inside2)
temperature.
Displays the Thermostat Mode
HOLD, SCHEDULE or VACANT
Displays the time, day and schedule
MORNING, DAYTIME, EVENING
or NIGHT
MENU
Key Displays
the User options.
Displays the upstairs airflow
Displays the Airflow Mode
AUTOMATIC or MANUAL
Displays the heating or
cooling temperature
FAN MODE
Key
AUTO or ON
Installer Manual
Model C365W21 and C365W21WF
365
Comfort
Ver.1.9 Jun 2017
Displays the downstairs airflow
NEXT
Key
Used to advance through options
ENTER
Key
Used to save options and
return to thermostat operation
Wireless Technology
Link
e
MODE
Key
Selects Thermostat Mode
HOLD, SCHEDULE or VACANT
i
If needed, airflow control can be disabled using
Option 17. The thermostat will control the system like
any other thermostat, and the nighttime airflow option
will be disabled.
i
The C365 wireless thermostat controls heating, cooling and
airflow to the upstairs and downstairs using an upstairs and
downstairs wireless, modulating damper. A wireless, battery
powered temperature sensor located upstairs monitors the
upstairs temperature and the temperature sensor in the C365
monitors the downstairs temperature.
The C365 adjusts the upstairs and downstairs airflow during
heating and cooling calls to maintain uniform upstairs and
downstairs temperatures.
SYSTEM MODES
Off, Heat, Cool, Auto
THERMOSTAT MODES
Hold, Schedule or Vacant mode.
PROGRAMS PER DAY
Morning, Daytime, Evening and Night.
PROGRAM FORMAT
Weekdays and weekend– 5/2.
TEMPERATURE OVERRIDE
Temperature is held for 4 hours
when adjusted in Schedule mode.
FAN MODES
Auto or Continuous
AIRFLOW CONTROL
Airflow can be turned off using Option
17. Dampers fully open, nighttime airflow options are disabled
and airflow is no longer displayed on the thermostat.
AIRFLOW LIMITS
Maximum upstairs and downstairs, heating
and cooling airflow limits can be set during installation.
NIGHTTIME OPERATION
The C365 thermostat uses the
upstairs temperature sensor to control heating and cooling
calls and directs more airflow upstairs. If bedrooms are located
downstairs, the Nighttime Airflow option should be turned off.
COMPATIBLE EQUIPMENT
Gas/electric equipment with 2-
stage heating and 1-stage cooling or 1-stage heating and 2-
stage cooling and heat pumps with 2-stage heating and 2-
stage cooling.
UPSTAIRS TEMPERATURE SENSOR
One or two TS5WL
upstairs wireless temperature sensors can be used.
MODULATING DAMPERS
Round or rectangular dampers
using the A80WL2 actuator and up to 1 inch static pressure.
POWER
Operates on 24VAC from the HVAC equipment using
the R and C wires.
ATTENTION INSTALLER
i
Nighttime Airflow Option. If bedrooms are located
downstairs, the Nighttime Airflow Option should be
turned OFF using the User Options.
i
Set Options (p.5-7). Options 1 through 5 determine the
equipment operation and must be set if different than
Factory Settings.
After installing dampers and sensors and setting up
wireless communication to the thermostat,
CHECK FOR ERROR MESSAGES (p.4)
Set time of day (p.4).
i
i
The thermostat location must be changed using
Option 27 if the thermostat is located upstairs in
the bedroom area.
i
Homes with plaster walls with steel lathe may
experience wireless communication interference.
i
The Home number must be changed if two wireless
installations are within 300 feet of each other. See
page 3 and page 7, Option 26.