3
3
WARNING:
This heater has a voltage rating of 120 volts. The cord
has a 3-prong grounding-type plug (A) which fits the 3-slot grounded
receptacle (A2). DO NOT remove the grounding prong (A1) if only a
2-slot receptacle (B) is available.
For connecting 3-prong grounding-type plug to 2-slot receptacle, use
an ADAPTER (C). The grounding lug (C1) extending from the adapter
must be connected to a permanent ground with the Metal Screw (D)
such as a properly grounded outlet box (E).
The adapter should not be used if a 3-slot grounded receptacle is
available.
DO NOT DEFEAT THE SAFETY PURPOSE OF EITHER
A GROUNDED PRONG OR A GROUNDED LUG.
(A)
(A2)
(B)
(A1)
(C)
(D)
(E)
(C1)
Adapter is not included
WARNING:
ELECTRICAL SHOCK HAZARD
Do not use with damaged cord or plug. Use with adequate
electrical system that is up to code.
CAUTION:
PREVENT LECTRICAL SHOCK
This product has a three prong grounded plug that must be
inserted into a matching properly grounded outlet to reduce
the risk of electrical shock. Do not attempt to defeat this safety
feature.
DO NOT
operate any heater with a damaged cord or plug or
after heater malfunctions, has been dropped or damaged in any
manner. Do not operate heater with a broken heating element
or ceramic cone or any visual imperfections. Disconnect power
before servicing. For repairs covered under warranty, see
warranty statement. For all other repairs contact Comfort Zone
®
Customer Service by telephone or mail for information and
assistance.
PET OWNERS NOTE
The health of birds and some small pets are extremely
sensitive to the fumes given off during the initial use of many
appliances. Although these fumes are not harmful to humans,
it is recommended that this heater not be used around birds and
small pets during its initial use until the manufacturing corrosion
coatings burn off.
HEATER INSTALLATION
ATTENTION!
• This heater should be handled gently during installation and while
cleaning.
• Do not install in an acidic or alkaline environment.
• The heater must be grounded.
• The installer is required to check the product brand mark on the
voltage and check that the local voltage is appropriate.
• Ensure the power rating has sufficient current carrying capacity.
WARNING:
Any electrical wiring for the heater that has to be done
should be completed by a qualified specialist.
WALL MOUNTING
1. For safety, the unit
should be mounted
at least 6 ft above the
ground. It should be
installed at least 18"
away from the ceiling or
roof, and should be at
least 18" from a wall or
structure to the left and
the right of the mounted
heater (Fig. 1).
3. Using the screws provided, screw the wall brackets into the brackets
on the heater, using a nut to tighten. Be sure to adjust the heater
angle before tightening the screws so that the heat is directed to the
area being heated (Fig. 3 and Fig. 3a).
2. Using a drill, make three 8 mm round holes and insert three plastic
wall anchors into the holes (Fig. 2 and 2a). The two wall brackets
should be screwed into the wall at an appropriate distance so that
they can attach to the brackets on the heater.
Fig. 2
Fig. 2a
Fig. 3a
Fig. 3
OPERATING INSTRUCTIONS
Manual Operation:
Use the rocker power switch on the right to
manually control the heater if you don't have
the remote control nearby.
•
Position « I »
powers on the heater and keeps
it on HIGH heat setting.
•
Position « O »
powers off the heater.
On/Off
Low
High
Medium
Remote Control Operation:
Once the
Position « I »
is selected on the
rocker power switch. You can adjust the
heat setting using the remote control.
• ON/OFF – Switches the heater on or off
or puts it in standby mode.
• After turning on the heater, you can
choose LOW, MEDIUM or HIGH setting
by pressing the corresponding wattage
button on the remote.
6 ft.
18 in.
18 in.
Fig. 1