Comfort Zone CZBC Series Manual Download Page 3

3

3

www.comfortzoneproducts.com

SPECIFICATIONS:

Please refer to the correct model for specifications:

NOTE: 

Receptacles, Timers and GFCI Plugs only available on select models.

PRODUCT OVERVIEW:

OPERATING INSTRUCTIONS:

The air mover is ready to use, out of the box – no assembly  
required. It is intended to move air and dry floors, walls, furniture, 
crawl spaces, basements, etc. The air mover is powerful,  
durable and easy‑to‑operate, making it suitable for a variety of 
applications.
1.  Before plugging into an electrical outlet, make sure the air 

mover does not have visible damage Place the air mover on 
a stable, flat, dry surface. 

2.  Position the air mover to the surface that needs to be dried.  

This air mover is able to be used at 3 different angles for 
optimal air flow.

3.  Plug the power cord into the electrical outlet and turn the 

switch to select the desired speed.

4.  Please make sure the air mover is supervised at all times 

while operating. 

DAISY CHAINING:

•  Some models come equipped with additional receptacles on 

the unit, providing the ability to connect a series of air movers 
(or other appliances) together using a single connection at the 
outlet. These air movers/appliances will work whether the air 
mover is on or off. Please note that the total amperage must 
be lower than the 12 amps on the circuit breaker.

•  If the air mover is plugged in and stops working, press the 

RESET button to reset the circuit.

GFCI PLUG:

•  Some models come equipped with a GFCI plug.
•  A ground fault circuit interrupter (GFCI) plug will automatically 

shut off power directly at the power source when it detects an 
electrical fault.

•  If the plug trips, push the reset button on the GFCI plug to get 

it working again.

•  To test your GFCI plug press the button labeled 'test'. If the air 

mover stops working, your GFCI is working properly. To make 
it active again, simply press the 'reset' button.

TIMER FUNCTION:

•  Some models have a timer function that will turn the air mover 

OFF after a specified time.  

•  Turn the TIMER knob to set the preferred time from 1 minute 

up to 180 minutes (3 hours), or anywhere in between. The 
TIMER function will count down the time and turn the air mover 
OFF once set time is reached.

ADJUSTABLE ANGLES:(SELECT 

MODELS)

MODEL

CZBC141

CZBC131G CZBC121T

CZBC101T

Power

1/4 HP

1/3 HP

1/2 HP

1 HP

Amp

1.8

2.8

4.5

6.9

Speeds

3

3

3

3

Daisy Chain

Yes

No

No

No

Plug Type

Grounded

GFCI

Grounded

Grounded

Timer

No

No

Yes

Yes

Cord
Length

14 AWG 
10 ft.

18 AWG 
20 ft.

18 AWG 
20 ft.

18 AWG 
25 ft.

Overheat 
Protection

Thermally 
Protected

Thermally 
Protected

Thermally 
Protected

Thermally 
Protected

Rated Airflow 800 CFM

1250 CFM

1500 CFM

1900 CFM

Tilt Angle

0°, 45°, 90°

0°, 45°, 90°

0°, 45°, 90°

Weight

10.9 lbs.

25.6 lbs.

26.5 lbs.

34 lbs.

Reset Button

45°

90°

Receptacle (Select Models)

Rubber Feet

Receptacle (Select Models)

3 Hour Timer

Convenient Carry

Handle & Cord Wrap

Speed Selector
Switch

Grounded Cord or GFCI Plug

(Select Models)

This air mover has 3 operating angles that allow you to 
blow air at 0, 45 and 90 degree angles.

Reviews: