1
VENT-FREE
GAS LOG SET
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A
FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY
OR LOSS OF LIFE.
WARNING:
This appliance
is equipped for (Natural
and Propane) gas. Field
conversion is not permitted
other than between natural or
propane gases.
- Do not store or use gasoline or other flammable vapors and Iiquids in vicinity of this or
any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the
gas supplier.
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion and ventilation air must be provided.
Refer to Air For Combustion and Ventilation section on page 9 of this manual.
This appliance may be installed in an aftermarket, permanently located manufactured (mobile)
home, where not prohibited by local codes. This appliance is only for use with propane or natural
gas. This appliance is equipped with a simple means to switch between propane and natural gas.
Field conversion by any other means including the use of a kit is not permitted.
Dual Fuel
ANSI Z21.11.2-2013
80-10-433 - 2018-01-11
Questions, problems, missing parts?
Before returning to your retailer, call our
Technical Service Department at 1-814-643-1775.
CAUTION - FOR YOUR SAFETY
C US
C US
®
WARNING: Do not attempt to access or change the setting of the fuel selection means.
Access to and adjustment of the fuel selection means must only be a performed by a
qualified service person when connecting this appliance to a specified fuel supply at the time
of installation.
Change of the selector setting to other than the fuel type specified at the time of installation
could damage this appliance and render it inoperable.
The installer shall replace the access cover before completing the installation and operating
this appliance.
The Installation instructions for an appliance for installation on combustible flooring shall
specify that when the appliance is installed directly on carpeting, tile or other combustible
material, other than wood flooring, the appliance shall be installed on a metal or wood panel
extending the full width and depth of the appliance.
MODEL # GLD1856T
GLD2456T
Patent Pending Dual
Fuel System
NG
LP