Comfort Glow EQS130 Installation & Operating Instructions Manual Download Page 4

4

SAFETY INFORMATION

Electrical Connection

Grounding Instructions

This heater is for use on 120 volts. The cord has a plug as shown at (A) in figure 1. 

An adaptor as shown at (C) is available for connecting three-blade grounding-type 

plugs to two-slot receptacles. The green grounding lug extending from the adaptor 

must be connected to a permanent ground such as a properly grounded outlet box. 

The adaptor should not be used if a three-slot grounded receptacle is available.

NOTE:  Adaptors are NOT  

 

for use in Canada.

DANGER

A 15 Amp, 120 Volt, 60 Hz circuit with a properly grounded outlet is required.  

Preferably, the fireplace will be on a dedicated circuit as other appliances on the  

same circuit may cause the circuit breaker to trip or the fuse to blow when the heater 

is in operation. The unit comes standard with a 6 ft. (1.8 m) long, three-wire cord,  

exiting the right side of the fireplace. Always plug the unit into a wall outlet/receptacle. 

An extension cord or re-locatable power tap, (outlet/power strip), should never be 

used.

Electrical outlet wiring must comply with local building codes and other  

applicable regulations to reduce the risk of fire, electrical shock and injury  

to persons.
Do not use this fireplace if any part of it has been under water. Immediately  

call a qualified service technician to inspect the fireplace and replace any part  

of the electrical system which has been under water.

Figure 1

GROUNDING          

PIN

 

METAL SCREW

GROUNDING

    MEANS

 

COVER OF GROUNDED

OUTLET BOX

ADAPTER

GROUNDING

PIN

(A)

(B)

(D)

(C)

Summary of Contents for EQS130

Page 1: ...ONSUMER Retain this manual for future reference WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY AN ELECTRICAL SHOCK OR FIRE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS...

Page 2: ...ting Instructions before using this appliance TABLE OF CONTENTS Safety Information 3 4 Package Contents 5 Hardware Contents 5 Stove Dimensions 6 Safety Information 7 Preparation 7 Assembly Instruction...

Page 3: ...tc 11 Do not run cord under carpeting Do not cover cord with throw rugs runners or the like Arrange cord away from traffic areas and where it will not be tripped over 12 To disconnect this appliance t...

Page 4: ...other appliances on the same circuit may cause the circuit breaker to trip or the fuse to blow when the heater is in operation The unit comes standard with a 6 ft 1 8 m long three wire cord exiting t...

Page 5: ...5 PACKAGE CONTENTS A B A Electric Stove 1 B Leg 4 PART DESCRIPTION QUANTITY HARDWARE CONTENTS shown actual size Screw Qty 8 AA...

Page 6: ...6 STOVE DIMENSIONS TECHNICAL SPECIFICATIONS Voltage 120V AC Frequency 60Hz Amps 12 5A Rating 1500W REF EQS5140 A 11 in 27 94 cm B 23 in 58 42 cm C 20 in 50 8 cm A B C...

Page 7: ...mbly of product make sure all parts are present Compare parts with package contents list and hardware contents above If any part is missing or damaged do not attempt to as semble the product Contact c...

Page 8: ...glow Flame effect will be visible through the front glass Temperature Toggle Temperature Switch ON the Temperature control knob regulates the temperature level of the room The further the knob is rot...

Page 9: ...red glass Replacement of the glass supplied by the manufacturer should be done by a qualified service person Light Bulb Inspection and Replacement The flame effect is created by two 40 Watt light bulb...

Page 10: ...al Code ANSI NFPA No 70 If repairing or replacing any electrical component or wiring the original wire routing color coding and securing locations must be followed DANGER Any electrical repairs or rew...

Page 11: ...Incorrect operation 2 Defective heater switch 3 Defective heater assembly 4 Loose wiring 5 Dirty or clogged vents 6 The thermostat is satisfied 1 Make sure the stove is plugged in to a standard 120V o...

Page 12: ...by this warranty nor shall the manufacturer assume responsibility for same Further the manufacturer will not be responsible for any incidental indirect or consequential damages except as provided by l...

Page 13: ...cess panel Thermostat Top panel Light barrier panel Screen Hinge Pin 22 14 17 19 12 Side glass Lamp socket bracket Flame reflector Power cord connector Cabinet panel Control panel switch Flame panel L...