background image

8

104269

VENT-FREE NATURAL GAS HEATER

Installing Two Mounting Screws

Note:

 Wall anchors and mounting screws

are in hardware package. The hardware pack-
age is provided with heater.

Attaching To Wall Stud Method

For attaching mounting screw to wall stud

1.

Drill hole at marked location using 9/64"
drill bit.

2.

Insert mounting screw into wall stud.

3.

Tighten screw until 1/16" space (thick-
ness of penny) is between screwhead
and wall.

Attaching To Wall Anchor Method

Follow instructions below to attach mount-
ing screws to hollow walls (wall areas be-
tween studs) or solid walls (concrete or
masonry).

1.

Drill holes at marked locations using
5/16" drill bit. For solid walls (concrete
or masonry), drill at least 1 

1

/

4

" deep.

2.

Fold wall anchor (see Figure 6).

3.

Insert wall anchor (wings first) into
hole. Tap anchor flush to wall.

4.

For thin walls (1/2" or less), insert red
key into wall anchor. Push red key to
“pop” open anchor wings (see Figure 7).

IMPORTANT:

 Do not hammer key!

For thick walls (over 1/2" thick) or solid
walls, do not pop open wings.

5.

Tighten two screws until 1/16" space
(thickness of penny) is between
screwheads and wall (see Figure 8).

INSTALLATION

Continued

Figure 8 - Tightening Anchors

1/16"
Space

Thin or
Thick Wall
(thick wall
shown)

Solid Wall

Thin Walls (1/4" to 1/2" thick)

Figure 7 - Popping Open Anchor Wings
For Thin Walls

Figure 6 - Folding Anchor

Placing Heater On Mounting
Screws

1.

Locate two keyhole slots on back panel
of heater (see Figure 9).

2.

Place large openings of slots over
screwheads. Slide heater down until
screws are in small portion of slots.

Figure 11 - Installing Bottom Mounting
Screw

Removing Front Panel Of Heater

1.

Remove two screws near bottom cor-
ners of front panel.

2.

Lift straight up on grill guard until it stops.
Grill guard will slide up about 1/4".

3.

Pull bottom of front panel forward, then
down.

Figure 10 - Removing Front Panel Of
Heater

Installing Bottom Mounting
Screw

1.

Locate bottom mounting hole. This
hole is near bottom on back panel of
heater (see Figure 11).

2.

Mark screw location on wall.

3.

Remove heater from wall.

4.

If installing bottom mounting screw
into hollow or solid wall, install wall
anchor. Follow steps 1 through 5 un-
der Attaching To Wall Anchor Method.
If installing bottom mounting screw
into wall stud, drill hole at marked lo-
cation using 9/64" drill bit.

5.

Replace heater on wall.

6.

Insert bottom anchor screw through
back panel into bottom anchor or drilled
hole (see Figure 11).

7.

Tighten screw until heater is firmly se-
cured to wall. Do not over tighten.

Note:

 Do not replace front panel at this

time. Replace front panel after making
gas connections and checking for leaks
(see pages 9 and 10).

Keyhole
Slots

Figure 9 - Location Of Keyhole Slots On
Back Panel Of Heater

Summary of Contents for CGN10LA

Page 1: ... service must be per formed by a qualified installer service agency or the gas supplier WARNING Improper instal lation adjustment alteration service or maintenance can causeinjuryorpropertydam age Refer to this manual for correct installation and op erational procedures For as sistance or additional infor mation consult a qualified in staller serviceagency orthe gas supplier WARNING This is an unv...

Page 2: ...un properly This heater has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the heater if not enough fresh air is available See Air for Combustion and Ventilation pages 4 through 6 5 Keep all air openings in front and bot tom of heater clear and free of debris This will insure enough air for proper combustion 6 If heater shuts off do not relight until you provide fresh out...

Page 3: ...gnitor Button 1 Remove heater from carton 2 Remove all protective packaging ap plied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater PRODUCT FEATURES SAFETY DEVICE This heater has a pilot with an Oxygen DepletionSensing ODS safetyshutoffsys tem The ODS pilot is a required feature for vent freeroomheaters TheODS pilot...

Page 4: ...of one perm 6 x 10 11 kg per pa sec m2 or less with open ings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking or sealants are applied to areas such as joints around window and door frames be tween sole plates and floors be tween wall ceiling joints be tween wall panels at penetra tions for plumbing electrical and gas lines and at other opening...

Page 5: ...f all fuel burning appliances in the space Vent free heater _____________ Btu Hr Gas water heater _____________ Btu Hr Gas furnace _____________ Btu Hr Vented gas heater _____________ Btu Hr Gas fireplace logs _____________ Btu Hr Other gas appliances _____________ Btu Hr Total _____________ Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and ven...

Page 6: ...Figure 2 Ventilation Air from Inside Building WARNING Rework work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both spaces Figure 3 Ventilation Air from Outdoors Outlet Air Ventilated Attic Outlet Air Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Ventilation Air From Outdoors Provide extra f...

Page 7: ...h as to bacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may discolor walls WARNING Never install the heater inabathroom ModelCGN10LA only CGN6LA is allowed in bathroom Checklocalcodes in a recreational vehicle where curtains furniture clothing or other flammable objects are less than 36 inches from the front top or sides of the heater as a fireplace insert i...

Page 8: ...o 1 2 thick Figure 7 Popping Open Anchor Wings For Thin Walls Figure 6 Folding Anchor Placing Heater On Mounting Screws 1 Locate two keyhole slots on back panel of heater see Figure 9 2 Place large openings of slots over screwheads Slide heater down until screws are in small portion of slots Figure 11 Installing Bottom Mounting Screw Removing Front Panel Of Heater 1 Remove two screws near bottom c...

Page 9: ...ible location The equip ment shutoff valve is for turning on or shutting off the gas to the appliance Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves Installsedimenttrapinsupplylineasshown in Figure 12 Locate sediment trap where it is within reach for cleaning Locate sedi ment trap w...

Page 10: ...osition 4 Check all joints from equipment shutoff valve to control valve see Figure 14 Applymixtureofliquidsoapandwaterto gas joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light heater see Operating Heater pages 10 and 11 Check the rest of the internal joints for leaks 7 Turn off heater see To Turn Off Gas to Appliance page 11 8 Replace front panel Figure 13 Equipment Shutoff Va...

Page 11: ...utton until pilot lights Note If pilot does not stay lit refer to Troubleshooting pages 13 through 15 Also contact a qualified service personorgassupplierforrepairs Un til repairs are made light pilot with match To light pilot with match see Manual Lighting Procedure 7 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Note If pilot goes out repe...

Page 12: ... lint from carpeting bedding material pet hair etc CABINET Air Passageways Use a vacuum cleaner or pressurized air to clean Exterior Use a soft cloth dampened with a mild soap and water mixture Wipe the cabi net to remove dust ODS PILOT AND BURNER ORIFICE Use a vacuum cleaner pressurized air or small soft bristled brush to clean CLEANING BURNER PILOT AIR INLET HOLE We recommend that you clean the ...

Page 13: ...mocouple to cool causing pilot flame to go out This prob lem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Replace ignitor 2 Replace ignitor 3 Reconnect ignitor cable 4 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 5 Tighten nut holding piezo ignitor to ...

Page 14: ...apors from furniture pol ish wax carpet cleaners etc turn into white powder residue REMEDY 1 Clean burner orifice see Cleaning and Maintenance page 12 or replace burner orifice 2 Replace burner orifice 3 Contact local natural gas company 1 Contact local natural gas company 2 Clean burner orifice see Cleaning and Maintenance page 12 or replace burner orifice 1 Clean burner orifice see Cleaning and ...

Page 15: ...nections page 10 1 Refer to Fresh Air for Combustion and Ventilation requirements page 4 OBSERVED PROBLEM Heater produces a clicking ticking noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion Moisture condensationnoticedonwindows POSSIBLE CAUSE 1 Metal expanding...

Page 16: ...contact your nearest Parts Central or call DESA International s Parts Department at 1 800 972 7879 for referral information When calling DESA International have ready model number of your heater the replacement part number REPLACEMENT PARTS SPECIFICATIONS SERVICE PUBLICATIONS Youcanpurchaseaservicemanualfromthe address listed on the back page of this manual Send a check for 5 00 payable to DESA In...

Page 17: ...x 616 791 8270 www nbmc com Dayton Hardware P O Box 275 North Dayton Station Dayton OH 45404 0275 All States 937 258 3721 OH 1 800 762 3426 Halco Enterprises 208 Carter Drive Unit 21 West Chester PA 19382 4500 610 430 7717 1 800 368 0803 www halcoenterprises com LA Porte s Parts Service 2444 N 5th Street Hartsville SC 29550 7704 803 332 0191 Parts Department Cans Unlimited Inc P O Box 645 Taylor S...

Page 18: ...18 104269 VENT FREE NATURAL GAS HEATER 12 2 12 1 ILLUSTRATED PARTS LIST CGN10LA CGN6LA 10 12 11 1 2 3 4 5 6 7 9 8 10 13 14 15 17 18 21 22 25 20 24 23 19 26 27 16 ...

Page 19: ...1 11 098249 01 098249 01 Nut M5 2 12 099440 03 100701 03 ODS Pilot Assembly 1 12 1 098514 01 098514 01 Thermocouple 1 12 2 098594 01 098594 01 Ignitor Electrode 1 13 104263 01 104263 01 Burner 1 14 099387 05 099387 05 Pilot Tubing 1 15 104259 03 104259 01 Injector 1 Piece 1 16 NJF 8C NJF 8C Hex Nut 1 17 099415 14 099415 14 Pressure Regulator 1 18 099462 01 099462 01 Burner Tubing 1 19 099391 02 09...

Page 20: ...conditionbecauseofnormalwearandtear orpartsthatfailorbecome damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS TH...

Reviews: