OWNER’S MANUAL

INSTALLATION

Continued

Figure 11 - Attaching Flexible Gas Hose
to Heater Gas Regulator

4.

Remove heater base from fireplace.

5.

Drill holes at marked locations using
3/16" drill bit. Drill at a 45° angle.

6.

Attach base to fireplace floor using
masonry screws in hardware
package (see Figure 12).

7.

Connect to gas supply. See Connect-
ing To Gas Supply
.

Figure 12 - Attaching Heater to Fireplace
Floor

CONNECTING TO GAS
SUPPLY

 WARNING: A qualified ser-

vice person must connect heater
to gas supply. Follow all local
codes.

Installation Items Needed

Before installing heater, make sure you have
the items listed below.

• piping (check local codes)

• sealant (resistant to propane/ LP gas)

• manual shutoff valve *

• test gauge connection *

• sediment trap

• tee joint

• pipe wrench

*  An CSA design-certified manual shutoff
valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Pur-
chase the optional CSA design-certified
manual shutoff valve from your dealer. See
Accessories, page 22.

Continued

Heater Gas
Regulator

Flexible Gas Hose (if
allowed by local codes)

Masonry
Screw

 CAUTION: Avoid damage to

regulator. Hold gas regulator with
wrench when connecting it to gas
piping and/or fittings.

 WARNING: Never connect

heater to private (non-utility) gas
wells. This gas is commonly
known as wellhead gas.

Installation must include a manual shutoff
valve, union, and plugged 1/8" NPT tap.
Locate NPT tap within reach for test gauge
hook up. NPT tap must be upstream from
heater (see Figure 13).

Apply pipe joint sealant lightly to male
threads. This will prevent excess sealant
from going into pipe. Excess sealant in pipe
could result in clogged heater valves.

 CAUTION: Use only new,

black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of 1/2"
diameter or greater to allow
proper gas volume to heater. If
pipe is too small, undue loss of
pressure will occur.

We recommend that you install a sediment
trap in supply line as shown in Figure 13.
Locate sediment trap where it is within
reach for cleaning. Install in piping system
between fuel supply and heater. Locate sedi-
ment trap where trapped matter is not likely
to freeze. A sediment trap traps moisture
and contaminants. This keeps them from
going into heater controls. If sediment trap
is not installed or is installed wrong, heater
may not run properly.

 CAUTION: Use pipe joint seal-

ant that is resistant to liquid pe-
troleum (LP) gas.

Tee

Pipe

Joint

Cap

Nipple

Figure 13 - Gas Connection

* Purchase the optional CSA design-certi-
fied manual shutoff valve from your dealer.
See Accessories, page 22.

** Minimum inlet pressure for purpose of
input adjustment.

3" Minimum

Sediment Trap

From Gas
Meter
(5" W.C.** to
10.5" W.C.
Pressure)

CSA Design-Certified
Manual Shutoff Valve
With 1/8" NPT Tap*

Approved
Flexible Gas
Hose (if allowed
by local codes)

Gas
Regulator

Summary of Contents for CGG2618N

Page 1: ...nd Ventilation section page 4 in this manual WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do...

Page 2: ...sed before running heater 8 This log heater is designed to be smoke less If logs ever appear to smoke turn off heater and call a qualified service person Note During initial operation slight smoking c...

Page 3: ...ters State and local codes in some areas prohibit the use of vent free heaters Non thermostat models may also be operated as a vented decorative ANS Z21 60 product by opening flue damper SAFETY PILOT...

Page 4: ...ion However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings exposed to the outsid...

Page 5: ...rect vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________...

Page 6: ...e two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors orspacesopentotheoutdoors Thesespaces include attics and crawl spaces...

Page 7: ...air may cause mildew to form from too much moisture See Air for Com bustion and Ventilation pages 4 through 6 CHECK GAS TYPE Use only natural gas If your gas supply is not natural gas do not install...

Page 8: ...K No hood accessory needed Less than 8 Noncombustiblematerialmustbeextendedtoatleast8 See Between 8 and 12 above If you cannot extend material youmustoperateheaterwithfluedamperopen Figure 5 Heat Resi...

Page 9: ...7 when using hood Mantel Shelf INSTALLATION Continued Figure 7 Minimum Mantel Clearances When Using Hood Mantel Shelf Minimum Non Combustible Material 8 Min 12 15 18 All minimum distances are in inche...

Page 10: ...e floor If not heater will move when you adjust controls Moving heater may cause a gas leak INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION Note When used as a vented heater appli ance must be...

Page 11: ...de a manual shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 13 Apply pipe joint sealant lightly to male t...

Page 12: ...orrect all leaks at once WARNING Neveruseanopen flame to check for a leak Apply a mixture of liquid soap and water toalljoints Bubblesformingshow a leak Correct all leaks at once WARNING Test all gas...

Page 13: ...ddle log 2 see Figure 18 Make sure notches on bottom rest on grate prongs 4 Finally place top log 4 over bottom middle log 2 by matching the notches under log 4 with the raised blocks of log 2 see Fig...

Page 14: ...the front burner If needed keep press ing ignitor button until pilot lights Note If pilot does not stay lit con tact a qualified service person or gas supplier for repairs Until repairs are made light...

Page 15: ...s heater with glassdoorsclosed Ifyouoper ate heater with doors closed heatbuildupinsidefireplacewill cause glass to burst Also if fireplace opening has vents at the bottom you must open the vents befo...

Page 16: ...ilot does not light contact a qualified service person or gas sup plier for repairs Until repairs are made light pilot with match To light pilot with match see Manual Light ing Procedure column 3 7 Ke...

Page 17: ...air to mix with the gas This provides a clean burning flame Keep these holesclearofdust dirt andlint Cleanthese air inlet holes prior to each heating season Blocked air holes will create soot We rec...

Page 18: ...amaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind...

Page 19: ...fter a few hours of operation 1 Refer to Air for Combustion and Venti lation requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burners until air is removed...

Page 20: ...k SeeWarning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Thermostat sensing bulb needs to be r...

Page 21: ...not mount sensing bulb until step 5 If you have a masonry fire place see Figure 33 for location If you have a factory built metal fire place see Figure 34 for location If your fireplace has glass doo...

Page 22: ...Natural Gas Only Natural Gas Only Natural Gas Only Natural Gas Only Ignition Piezo Piezo Piezo Piezo Pressure 3 4 W C 3 4 W C 3 4 W C 3 4 W C Inlet Gas Pressure in of water Maximum 10 5 10 5 10 5 10 5...

Page 23: ...11 Parts Department East Coast Energy Products 707 Broadway W Long Branch NJ 07764 1542 732 870 8809 1 800 755 8809 Parts Department Tarantin Tank Co P O Box 6129 Freehold NJ 07728 6129 908 780 9340 1...

Page 24: ...AL GAS LOG HEATER 103424 ILLUSTRATED PARTS BREAKDOWN Variable Manually Controlled Models CGG2618N CGG3324N CGG3630N 18 20 19 26 25 21 21 27 5 6 7 8 29 29 25 10 9 11 12 13 15 22 23 27 1 27 2 24 7 1 7 2...

Page 25: ...098867 09 Gas Regulator 1 13 M11084 38 M11084 38 M11084 38 Screw 2 14 101011 01 101011 02 101011 03 Inlet Tube 1 15 098354 01 098354 01 098354 01 Control Knob 1 16 098462 03 098462 03 098462 03 Contr...

Page 26: ...ED NATURAL GAS LOG HEATER 103424 ILLUSTRATED PARTS BREAKDOWN Thermostat Controlled Model CGG3324NT 5 6 25 6 7 8 9 10 11 8 8 29 13 12 13 14 15 16 18 17 19 24 26 27 7 1 7 2 29 22 23 21 28 20 30 10 1 10...

Page 27: ...999 05 Rear Burner Assembly 1 12 101331 08 Base Assembly with decals 1 13 098271 06 Ignitor Cable 1 14 102445 01 Piezo Ignitor 1 15 098867 09 Gas Regulator 1 16 M11084 38 Screw 2 17 102810 02 Inlet Tu...

Page 28: ...r costs related to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY...

Reviews: