background image

13

107294

OWNER’S MANUAL

BURNER FLAME PATTERN

Figure 22 shows a correct burner flame pattern.
Figure 23 shows an incorrect burner flame
pattern. The incorrect burner flame pattern shows
yellow tipping of the flame. It also shows the
flame higher than 1/2 the glass panel height.

NOTICE: Do not mistake orange
flames with yellow tipping. Dust
or other fine particles enter the
heater and burn causing brief
patches of orange flame.

 WARNING: If yellow tipping

occurs, your heater could pro-
duce increased levels of carbon
monoxide. If burner flame pat-
tern shows yellow tipping, follow
instructions below.

1/2 GLASS HEIGHT

If burner flame pattern is incorrect, as shown
in Figure 23

• turn heater off (see To Turn Off Gas to

Appliance, page 11 for non-thermostat
models or page 12 for thermostat model)

• see Troubleshooting, pages 14 through 16

Figure 22 - Correct Burner Flame Pattern

Models CG10N and CGS10N
(Model CG6N will be lower due to lower
input rating)

1/2 GLASS HEIGHT

Yellow
Tipping

Figure 23 - Incorrect Burner Flame Pattern

CLEANING AND
MAINTENANCE

 WARNING: Turn off heater

and let cool before cleaning.

 CAUTION: You must keep

control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a quali-
fied service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting,
bedding material, pet hair, etc.

INSPECTING
BURNER

Check pilot flame pattern and burner flame
pattern often.

PILOT FLAME PATTERN

Figure 20 shows a correct pilot flame pattern.
Figure 21 shows an incorrect pilot flame
pattern. The incorrect pilot flame is not touch-
ing the thermocouple. This will cause the
thermocouple to cool. When the thermo-
couple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown
in Figure 21
• turn heater off (see To Turn Off Gas to

Appliance, page 11 for non-thermostat
models or page 12 for thermostat model)

• see Troubleshooting, pages 14 through 16

GRH/OV 007

GOOD PILOT/LP

MANUAL LIGHTING

PROCEDURE

1.

Follow steps 1 through 5 under Light-
ing Instructions
, page 12.

2.

With control knob pressed in, strike
match. Hold match to pilot until pi-
lot lights.

3.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Follow
step 8 under Lighting Instructions
,
page 12.

OPERATING
HEATER

Continued

ODS/PILOT AND BURNER

• Use a vacuum cleaner, pressurized air,

or small, soft bristled brush to clean.

CLEANING BURNER
PILOT AIR INLET HOLE

We recommend that you clean the unit every
2,500 hours of operation or every three months.

We also recommend that you keep the burner
tube and pilot assembly clean and free of dust
and dirt. To clean these parts we recommend
using compressed air no greater than 30 PSI.
Your local computer store, hardware store, or
home center may carry compressed air in a
can. You can use a vacuum cleaner in the
blow position. If using compressed air in a
can, please follow the directions on the can.
If you don't follow directions on the can,  you
could damage the pilot assembly.

1.

Shut off the unit, including the pilot.
Allow the unit to cool for at least thirty
minutes.

2.

Inspect burner, pilot for dust and dirt.

3.

Blow air through the ports/slots and
holes in the burner.

Clean the pilot assembly also. A yellow tip
on the pilot flame indicates dust and dirt in
the pilot assembly. There is a small pilot air
inlet hole about two inches from where the
pilot flame comes out of the pilot assembly
(see Figure 24). With the unit off, lightly
blow air through the air inlet hole. You may
blow through a drinking straw if compressed
air is not available.

Figure 24 - Pilot Inlet Air Hole

Pilot Assembly

Pilot Air Inlet
Hole

CABINET

Air Passageways

• Use a vacuum cleaner or pressurized air

to clean.

Exterior

• Use a soft cloth dampened with a mild

soap and water mixture. Wipe the cabi-
net to remove dust.

GRH/OV 008

BAD PILOT/LP

Thermocouple

Pilot Burner

Thermocouple

Pilot Burner

Figure 21 - Incorrect Pilot Flame Pattern

Figure 20 - Correct Pilot Flame Pattern

Summary of Contents for CG10N

Page 1: ...ndservicemustbeperformedby a qualified installer service agency or the gas supplier WARNING Thisisanunvented gas firedheater Itusesair oxy gen from the room in which it is installed Provisions for ad...

Page 2: ...ey are in the same room with heater Make sure grill guard is in place before running heater Keeptheapplianceareaclearand free from combustible materials gasoline and other flammable vapors and liquids...

Page 3: ...move all protective packaging ap plied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater PRODUCT FEATURES SAFETY DEVICE...

Page 4: ...tilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings exposed to the o...

Page 5: ...fuel burning appliances in the space Vent free heater ______________ Btu Hr Gas water heater ______________ Btu Hr Gas furnace ______________ Btu Hr Vented gas heater ______________ Btu Hr Gas firepl...

Page 6: ...owervent VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an adjoining unconfined space you must pro vide two permanent op...

Page 7: ...essthan36inchesfromthe front top or sides of the heater as a fireplace insert in high traffic areas in windy or drafty areas CAUTION If you install the heater in a home garage heaterpilotandburnermust...

Page 8: ...s or to solid walls concrete or masonry Decidewhichmethodbettersuitsyourneeds Eithermethodwillprovideasecureholdfor the mounting bracket Removing Front Panel Of Heater 1 Remove two screws near bottom...

Page 9: ...ectheater to private non utility gas wells This gas is commonly known as well head gas CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas Check...

Page 10: ...supply Check re connected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 14 2 Pressurize supply piping system by ei ther using com...

Page 11: ...sion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas con...

Page 12: ...at used on this heater senses the room temperature At times the room may exceed the set temperature If so the burner will shut off The burner will cycle back on when room temperature drops below the s...

Page 13: ...or thermostat model see Troubleshooting pages 14 through 16 GRH OV 007 GOOD PILOT LP MANUAL LIGHTING PROCEDURE 1 Follow steps 1 through 5 under Light ing Instructions page 12 2 With control knob press...

Page 14: ...ignitor button is pressed there is no spark at ODS pilot When ignitor button is pressed there is spark at ODS pilot but no ignition ODS pilot lights but flame goes out when control knob is released R...

Page 15: ...hours of operation 1 Turn control knob to LOW position and let warm up for a minute 2 Operate burner until air is removed from line Have gas checked by local natural gas company 3 Observe minimum inst...

Page 16: ...Contact local natural gas company 3 Clean ODS pilot see Cleaning and Maintenance page 13 1 Locate and correct all leaks see Check ing Gas Connections page 10 2 Replace control valve 1 Take apart gas t...

Page 17: ...the address listed on the back page of this manual Send a check for 5 00 payable to DESA International You may have further questions about in stallation operation or troubleshooting If so contact DES...

Page 18: ...date Usually we will ask you to return the defec tive part to the factory REPLACEMENT PARTS EQUIPMENT SHUTOFF VALVE GA5010 Equipmentshutoffvalvewith1 8 NPTtap ACCESSORY Purchase this heater accessory...

Page 19: ...y W Long Branch NJ 07764 1542 732 870 8809 1 800 755 8809 www njplaza com ecep Tarantin Tank Co P O Box 6129 Freehold NJ 07728 6129 908 780 9340 1 800 922 0724 www tarantin com Heater Fireplace Store...

Page 20: ...20 107294 NATURAL GAS HEATER 7 7 29 2 3 29 28 23 27 24 20 18 25 26 10 27 22 21 19 17 16 13 1 14 15 7 11 12 30 4 5 7 6 7 7 19 17 8 18 9 CG10N 25 2 25 1 ILLUSTRATED PARTS LIST ODS Pilot Assembly...

Page 21: ...lve Fixed Nut 1 12 L98061 05 Control Knob 1 13 L98029 03 Pressure Regulator 1 14 L98801 01 Washer 2 15 L98806 01 Self Tapping Screw 2 16 L98915 03 Pressure Tap Assembly 1 17 L98115 10 Main Inlet Tube...

Page 22: ...22 107294 NATURAL GAS HEATER CG6N 25 2 25 1 ILLUSTRATED PARTS LIST ODS Pilot Assembly 7 7 29 2 3 29 28 23 27 24 20 18 25 26 10 27 22 21 19 17 16 13 1 14 15 7 11 12 30 4 5 7 6 7 7 19 17 8 18 9...

Page 23: ...e Fixed Nut 1 12 L98061 05 Control Knob 1 13 L98029 03 Pressure Regulator 1 14 L98801 01 Washer 2 15 L98806 01 Self Tapping Screw 2 16 L98915 03 Pressure Tap Assembly 1 17 L98115 10 Main Inlet Tube As...

Page 24: ...24 107294 NATURAL GAS HEATER CGS10N 27 2 27 1 ILLUSTRATED PARTS LIST ODS Pilot Assembly 7 7 14 2 3 14 12 25 10 26 22 20 27 28 13 10 24 23 21 19 15 1 16 17 7 18 4 5 7 6 7 7 8 11 11 20 21 19 29 9...

Page 25: ...01 Nut 2 11 L98815 01 Screws 2 12 L98010 08 Grill 1 13 L98411 01 Ignitor Line 1 14 L98011 01 Grill Fastener 2 15 L99029 07 Pressure Regulator 1 16 L98801 01 Washer 2 17 L98806 01 Self Tapping Screw 2...

Page 26: ...he unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper mai...

Reviews: