background image

Save this manual for future reference.

BLUE FLAME VENT-FREE NATURAL GAS HEATER

OWNER’S OPERATION AND INSTALLATION MANUAL

 CG6N

CG10N

CGS10N

10,000 and 6,000 Btu/Hr

Thermostat and

Non-Thermostat Models

WARNING: If the information in this manual is
not followed exactly, a fire or explosion may
result causing property damage, personal in-
jury, or loss of life.

— Do not store or use gasoline or other

flammable vapors and liquids in the vicinity
of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not

use any phone in your building.

• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas
supplier’s instructions.

• If you cannot reach your gas supplier, call

the fire department.

— Installation and service must be performed by

a qualified installer, service agency, or the
gas supplier.

WARNING: This is an unvented
gas-fired heater. It uses air (oxy-
gen) from the room in which it
is installed. Provisions for ad-
equate combustion and venti-
lation air must be provided.
Refer to

 Air For Combustion

and Ventilation on page 4 of
this manual.

WARNING: Improper installa-
tion, adjustment, alteration,
service, or maintenance can
cause injury or property dam-
age. Refer to this manual for
correct installation and opera-
tional procedures. For assis-
tance or additional informa-
tion consult a qualified in-
staller, service agency, or the
gas supplier.

This appliance may be installed in an aftermarket*, permanently located, manufac-
tured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Summary of Contents for CG10N

Page 1: ...ndservicemustbeperformedby a qualified installer service agency or the gas supplier WARNING Thisisanunvented gas firedheater Itusesair oxy gen from the room in which it is installed Provisions for ad...

Page 2: ...ey are in the same room with heater Make sure grill guard is in place before running heater Keeptheapplianceareaclearand free from combustible materials gasoline and other flammable vapors and liquids...

Page 3: ...move all protective packaging ap plied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater PRODUCT FEATURES SAFETY DEVICE...

Page 4: ...tilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings exposed to the o...

Page 5: ...fuel burning appliances in the space Vent free heater ______________ Btu Hr Gas water heater ______________ Btu Hr Gas furnace ______________ Btu Hr Vented gas heater ______________ Btu Hr Gas firepl...

Page 6: ...owervent VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an adjoining unconfined space you must pro vide two permanent op...

Page 7: ...essthan36inchesfromthe front top or sides of the heater as a fireplace insert in high traffic areas in windy or drafty areas CAUTION If you install the heater in a home garage heaterpilotandburnermust...

Page 8: ...s or to solid walls concrete or masonry Decidewhichmethodbettersuitsyourneeds Eithermethodwillprovideasecureholdfor the mounting bracket Removing Front Panel Of Heater 1 Remove two screws near bottom...

Page 9: ...ectheater to private non utility gas wells This gas is commonly known as well head gas CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas Check...

Page 10: ...supply Check re connected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 14 2 Pressurize supply piping system by ei ther using com...

Page 11: ...sion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas con...

Page 12: ...at used on this heater senses the room temperature At times the room may exceed the set temperature If so the burner will shut off The burner will cycle back on when room temperature drops below the s...

Page 13: ...or thermostat model see Troubleshooting pages 14 through 16 GRH OV 007 GOOD PILOT LP MANUAL LIGHTING PROCEDURE 1 Follow steps 1 through 5 under Light ing Instructions page 12 2 With control knob press...

Page 14: ...ignitor button is pressed there is no spark at ODS pilot When ignitor button is pressed there is spark at ODS pilot but no ignition ODS pilot lights but flame goes out when control knob is released R...

Page 15: ...hours of operation 1 Turn control knob to LOW position and let warm up for a minute 2 Operate burner until air is removed from line Have gas checked by local natural gas company 3 Observe minimum inst...

Page 16: ...Contact local natural gas company 3 Clean ODS pilot see Cleaning and Maintenance page 13 1 Locate and correct all leaks see Check ing Gas Connections page 10 2 Replace control valve 1 Take apart gas t...

Page 17: ...the address listed on the back page of this manual Send a check for 5 00 payable to DESA International You may have further questions about in stallation operation or troubleshooting If so contact DES...

Page 18: ...date Usually we will ask you to return the defec tive part to the factory REPLACEMENT PARTS EQUIPMENT SHUTOFF VALVE GA5010 Equipmentshutoffvalvewith1 8 NPTtap ACCESSORY Purchase this heater accessory...

Page 19: ...y W Long Branch NJ 07764 1542 732 870 8809 1 800 755 8809 www njplaza com ecep Tarantin Tank Co P O Box 6129 Freehold NJ 07728 6129 908 780 9340 1 800 922 0724 www tarantin com Heater Fireplace Store...

Page 20: ...20 107294 NATURAL GAS HEATER 7 7 29 2 3 29 28 23 27 24 20 18 25 26 10 27 22 21 19 17 16 13 1 14 15 7 11 12 30 4 5 7 6 7 7 19 17 8 18 9 CG10N 25 2 25 1 ILLUSTRATED PARTS LIST ODS Pilot Assembly...

Page 21: ...lve Fixed Nut 1 12 L98061 05 Control Knob 1 13 L98029 03 Pressure Regulator 1 14 L98801 01 Washer 2 15 L98806 01 Self Tapping Screw 2 16 L98915 03 Pressure Tap Assembly 1 17 L98115 10 Main Inlet Tube...

Page 22: ...22 107294 NATURAL GAS HEATER CG6N 25 2 25 1 ILLUSTRATED PARTS LIST ODS Pilot Assembly 7 7 29 2 3 29 28 23 27 24 20 18 25 26 10 27 22 21 19 17 16 13 1 14 15 7 11 12 30 4 5 7 6 7 7 19 17 8 18 9...

Page 23: ...e Fixed Nut 1 12 L98061 05 Control Knob 1 13 L98029 03 Pressure Regulator 1 14 L98801 01 Washer 2 15 L98806 01 Self Tapping Screw 2 16 L98915 03 Pressure Tap Assembly 1 17 L98115 10 Main Inlet Tube As...

Page 24: ...24 107294 NATURAL GAS HEATER CGS10N 27 2 27 1 ILLUSTRATED PARTS LIST ODS Pilot Assembly 7 7 14 2 3 14 12 25 10 26 22 20 27 28 13 10 24 23 21 19 15 1 16 17 7 18 4 5 7 6 7 7 8 11 11 20 21 19 29 9...

Page 25: ...01 Nut 2 11 L98815 01 Screws 2 12 L98010 08 Grill 1 13 L98411 01 Ignitor Line 1 14 L98011 01 Grill Fastener 2 15 L99029 07 Pressure Regulator 1 16 L98801 01 Washer 2 17 L98806 01 Self Tapping Screw 2...

Page 26: ...he unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper mai...