background image

www.desatech.com

115043-01D

18

ACCESSORIES

Purchase these log set accessories from your local 

dealer. If they can not supply these accessories, call 

DESA at 1-866-672-6040 for referral information. 

You can also write to the address listed on the back 

page of this manual.

EQUIPMENT SHUTOFF VALVE 
GA5010

For all models.

 Equipment shutoff valve with 

1/8" NPT tap. Fits 1/2" NPT pipe.

RECEIVER AND HAND-HELD 
ON/OFF REMOTE CONTROL KIT 
HRC101

For all models.

 Allows the gas log set to be turned 

on and off by using the hand-held remote control. 

A  wall  mounted  docking  station  is  included. 

Valve/Pilot Kit GA9150A must be purchased to 

use this remote.

WALL-MOUNT ON/OFF SWITCH  
GWMS2 (Not Shown)

For all models.

 Allows the gas log set to be turned 

on and off with a wall switch. Valve/Pilot Kit 

GA9150A must be purchased to use this remote.

MANUAL CONTROL ON/OFF SAFETY 
VALVE/PILOT KIT - GA9050A  
(Not Shown)

For all models. 

Contains components for pro-

pane/LP conversion.

REMOTE CONTROL READY ON/
OFF SAFETY VALVE/PILOT KIT  
GA9150A (Not Shown)

For  all  models.

  Required  for  remote  control 

operation. Contains components for propane/LP 

conversion.

INDIVIDUAL ROUND LOG - GA9450A 
(Not Shown)

For decorative purposes only

. Not to be used as 

additional logs on unit.

INDIVIDUAL SPLIT LOG - GA9550A 
(Not Shown)

For decorative purposes only.

 Not to be used as 

additional logs on unit.

PINE CONES - GA9650A  
(Not Shown)

For all models. 

Use for additional decoration only. 

(3 pine cones per box).

ASH BED MATERIAL VERMICULITE) 
GA9750A (Not Shown)

For all models

. Use for firebox decoration only.

GLOWING EMBERS - GA9950A  
(Not Shown)

For all models.

 Use for firebox decoration only.

SILICA SAND - GA9850A 
(Not Shown)

For all models.

 Use for firebox decoration only.

LAVA ROCK - GA6067A 
(Not Shown)

For all models.

 Use for firebox decoration only.

DECORATIVE ASH BED CONTROL 
COVER - CDABKA (Not Shown)

An  attractive  way  to  cover  control  knob  and 

piezo ignitor.

18" ORNAMENTAL GRATE 
ENHANCER - GA9350A  
(Not Shown)

For 18" models only.

 Additional decoration for 

front grate.

24" ORNAMENTAL GRATE 
ENHANCER - GA9360A  
(Not Shown)

For 24" models only.

 Additional decoration for 

front grate.

FIRE CRACKLE - CF6-A 
(Not Shown)

For all models. 

Creates the sound of a real burn-

ing fire.

Summary of Contents for Brentwood LCF18

Page 1: ...o not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier...

Page 2: ...must be provided Refer to the National Fuel Gas Codes ANSI Z233 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation This appliance may be installed in an aftermarket per manently located manufact...

Page 3: ...micals known to the State of California to cause cancer or birth defects or other reproductive harm WARNING Keep flue open when operating unit IMPORTANT Read this owner s manual carefully and complete...

Page 4: ...tion 5 3 Air for Combustion and Ventilation 7 Do not run log set where flammable liquids or vapors are used or stored under dusty conditions 8 Do not burn solid fuel in the fireplace after installing...

Page 5: ...iance You must use the millivolt valve safety pilot kit to use the wall switch with this appliance See Accessories page 18 Installation CAUTION Donotremovethe dataplatesattachedtotheburner pan The dat...

Page 6: ...Observe the smoke and be sure the vent is properly drawing it up the chimney If the smoke spills out into the room extinguish the flame and remove any obstruction until proper venting is achieved The...

Page 7: ...em between fuel supply and appliance Locate sediment trap where trapped matter is not likely to freeze Asediment trap traps moisture and contaminants This keeps them from going into log set controls I...

Page 8: ...Figure 6 Tighten using a wrench 6 Using burner clamp screw and nut provided assemble clamp to pan U style and triple burners only This will hold the burner mani fold in place 7 If using optional GA905...

Page 9: ...ifold and reaming the ports with a modified paper clip or other suitable tool 5 When finished testing turn the gas shutoff valve OFF to extinguish all flames Adding Pan Material 1 Open the bag of ash...

Page 10: ...y call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department LIGHTING INSTRUCTIONS 1 STOP Read the safety info...

Page 11: ...the first time after hooking up to gas sup ply If so the control knob may need to be pressed in for 30 seconds This will allow air to bleed from the gas system If control knob does not pop up when rel...

Page 12: ...have your model and serial numbers of your appliance ready You can also visit DESA s technical services web site at www desatech com Replacement Parts Note Use only original replacement parts This wi...

Page 13: ...s to produce moderate levels of carbon soot where flames contact the logs Burner is excessively noisy Note The movement and com bustion of gas will create low unavoidable levels of noise Burner flame...

Page 14: ...LEM When ignitor button is pressed there is spark at pilot but no igni tion GA9050A Only Pilot lights but flame goes out when control knob is released GA9050A Only Burner does not light after pilot is...

Page 15: ...person 1 Open flue to maximum Stop using odor causing products while log set is running 2 Locate and correct all leaks see Checking Gas Connec tions page 7 1 Locate and correct all leaks see Checking...

Page 16: ...www desatech com 115043 01D 16 Illustrated Parts Breakdown Models LCF18 AND LCF24 3 13 1 8 6 4 2 10 7 5 9 9 11 12 14 20 15 16 19 18 17...

Page 17: ...Manifold 1 6 901137 01 Burner Pan 1 901137 02 Burner Pan 1 7 901242 01 Damper Clamp Std Assy 1 8 101628 01 Gas Line 10 Flex 1 9 901431 01 Grate Steps 2 10 901246 01 Log Grate 1 901246 02 Log Grate 1...

Page 18: ...ve Pilot Kit GA9150A Not Shown For all models Required for remote control operation Contains components for propane LP conversion Individual Round Log GA9450A Not Shown For decorative purposes only No...

Page 19: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 20: ...this warranty The log set MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in o...

Reviews: