background image

Comfortflame.US.com

900579-00_NC

11

Ignitor

Control Knob Pilot

FROM "PILOT" POSITION

SLIGHT PUSH TO 

TURN OFF 

PULL PUSH 

TO LIGHT

ON

ON

FROM "PILOT" POSITION

SLIGHT

 PUSH T

TURN OFF 

PULL

 PUSH 

TO LIGHT

FROM "PILOT" POSITION

SLIGHT

 PUSH T

TURN OFF  PULL

 PUSH 

TO LIGHT

ON

OFF

On

Off

OFF

OFF

Figure 18 - Ignitor and Control Knob

OPERATION

FOR YOUR SAFETY 

READ BEFORE LIGHTING

 WARNING: Keep flue open when operating unit.

 WARNING: If you do not follow these instructions 

exactly, a fire or explosion may result causing property 

damage, personal injury or loss of life.

BEFORE LIGHTING smell all around the appliance area for gas. Be 

sure to smell next to the floor because some gas is heavier than 

air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
•  Do not try to light any appliance.
•  Do not touch any electric switch; do not use any phone in your 

building.

•  Immediately call your gas supplier from a neighbor’s phone. 

Follow the gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire department.

LIGHTING INSTRUCTIONS

1.  STOP! Read the safety information, above.
2.  Turn the gas shutoff valve to OFF.
3.  Wait five (5) minutes to clear out any gas. If you then smell gas 

STOP! Follow the safety information above. If you don‘t smell gas, 

go on to the next step.

4.  Lay a lit match on top of pan material about 2" from end of supply 

side of  pan.

5.  Slowly turn gas shutoff valve ON until burner ignites. If burner 

does not ignite within 10 seconds with match burning, turn shutoff 

valve OFF and repeat steps 1 through 4 again.

GAS SHUTOFF 

VALVE OPERATION

Flame Adjustment

Adjust the flame ON/OFF by turning the gas shutoff valve counter-

clockwise 

 to open or clockwise 

 to close, as necessary.

Shutting Off Appliance

Turn gas shutoff valve clockwise 

 to the OFF position.

CURING 

LOGS

During the 2-3 hour appliance break-in period, you may detect an 

odor from the appliance as the various paints and compounds used 

in the manufacturing of this log set cure. This is a normal and tem-

porary situation that is not cause for alarm. However, you may want 

to provide extra ventilation to the room during this time.
To ensure proper curing of the logs:
•  Ignite a 2" flame and maintain it for 1 hour.
•  Burn the logs in consecutive 1 hour periods raising the flame an 

additional 2" to full flame height for a total of three hours.

OPERATING INSTRUCTIONS 

 FOR GA9050A-1 (F0235)

Note:

 Operation instructions for GA9150A (F0237) Remote Ready 

ON/OFF Safety Valve/Pilot Kit will be included with the kit.
1.  STOP! Read the safety information, column one.
2.  Make sure equipment shutoff valve is fully open.
3.  Press in and turn control knob clockwise 

 to the OFF posi-

tion.

4.  Wait five (5) minutes to clear out any gas. Then smell for gas 

around log set and near floor. If you smell gas, STOP! See safety 

information, page 3. If you don’t smell gas, go to the next step.

5.  Turn control knob counterclockwise 

 to the PILOT position 

and press in. Keep control knob pressed in for five (5) seconds.

 

Note:

 You may be running this log set for the first time after 

hooking up to gas supply. If so, the control knob may need to be 

pressed in for 30 seconds. This will allow air to bleed from the 

gas system.
• If control knob does not pop up when released, contact a quali-

fied service person or gas supplier for repairs.

6.  With control knob pressed in, push down and release ignitor 

button. This will light pilot. The pilot is attached to the rear of the 

front burner. If needed, keep pressing ignitor button until pilot 

lights.

 

Note:

 If pilot does not stay lit, contact a qualified service person 

or gas supplier for repairs. Until repairs are made, light pilot with 

match. 

7.  Keep control knob pressed in for 30 seconds after lighting pilot. 

After 30 seconds, release control knob.

 

Note:

 If pilot goes out, repeat steps 3 through 7. 

8.  Turn control knob counterclockwise 

 to the ON position. 

Burner should light. If burner does not light, call a qualified service 

person.

9.  To shut off burner only leaving pilot lit, turn control knob clockwise 

 to the PILOT position.

Summary of Contents for Sonoma18LZN

Page 1: ...ion and Ventilation These logs are approved by the manufacturer for installation in listed indoor and outdoor solid fuel burning fireplaces WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety wa...

Page 2: ...esale from the manufacturer State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Com monwealth of Massachusetts WARNING Thisproductcontainsand orgenerates ch...

Page 3: ...thafireplacescreen in place Make sure fireplace screen is closed before running this log set The screen shall have openings for introduction of combustion air Keep the appliance area clear and free fr...

Page 4: ...al Fire Protection Association Inc 1 Batterymarch Park Quincy MA 02169 7471 UNPACKING CAUTION Do not remove the data plates from the burner pan The data plates contain important war ranty and safety i...

Page 5: ...of your gas log set Please make sure that all of the specifications shown are applicable before installation is attempted The fireplace must include a working flue and venting system with the minimum...

Page 6: ...reater to allow proper gas volume to log set If pipe is too small undue loss of volume will occur Installation must include an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap with...

Page 7: ...8 Make sure the burner ports face downward 3 Using thread sealant resistant to the action of propane LP gas on larger end of fitting screw the burner inlet fitting through hole and into burner manifol...

Page 8: ...e burner pan assembly in center of fireplace floor Make sure front of pan faces the room from which you wish to control ap pliance 5 Thread gas supply fitting to fireplace gas supply pipe Adjust to mo...

Page 9: ...Propane LP Pilot Orifice Burner Inlet Fitting for Natural Gas NATURAL GAS FITTING PROPANE LP GAS FITTING Injector for Natural Gas Injector for Propane LP Gas Pilot Injector Changing Pilot Orifice The...

Page 10: ...Place grate over burner pan Grate should lock into place over corners of pan see Figure 15 2 Place one of the bottom logs on grate and slide forward against front grate bars Repeat for other side see...

Page 11: ...mpounds used in the manufacturing of this log set cure This is a normal and tem porary situation that is not cause for alarm However you may want to provide extra ventilation to the room during this t...

Page 12: ...is too low If so contact your local gas supplier TECHNICAL SERVICE You may have further questions about installation operation or troubleshooting Please contact your IHP dealer for any questions or co...

Page 13: ...e levels of carbon soot whereflamescontactthelogs Thisisespeciallytruewithpropane LPgas Burner is excessively noisy Note Themovementandcombustionofgas willcreatelow unavoidablelevelsofnoise Burner fla...

Page 14: ...eplace pilot assembly 5 Hand tighten until snug then tighten 1 4 turn more 6 Replace thermocouple 7 Replace control valve 1 Clean burner orifice 2 Contact local natural or propane LP gas company 3 Rec...

Page 15: ...ing orcontract ing while cooling 1 Log Set burning vapors from paint hair spray glues cleaners chemicals new carpet etc See IMPORTANT statement above 2 Gas leak See Warning statement at top of page 1...

Page 16: ...Comfortflame US com 900579 00_NC 16 PARTS 3 1 8 6 12 10 11 10 4 2 7 9 5 CATALOG NO MODEL F2615 Sonoma18LZN F2616 Sonoma24LZN...

Page 17: ...tural Gas Injector 1 5 J7323 Burner Manifold 1 J7322 Burner Manifold 1 6 J7329 Burner Pan 1 J7328 Burner Pan 1 7 J7287 Damper Clamp Std Assembly 1 8 J7286 Gas Line 12 Aluminum 1 9 J7331 Log Grate 1 J7...

Page 18: ...OG NO DESCRIPTION Sonoma18LZN F2615 Sonoma24LZN F2616 QTY 1 J7309 Bottom Log FC 8 2 J7310 Bottom Log FC 10 2 2 J7312 Bottom Log FC 9 2 J7313 Bottom Log FC 11 2 3 J7263 Top Log FS 12Y 1 4 J7262 Top Log...

Page 19: ...to be turned on and off by using the hand held remote control Valve Pilot Kit GA9150A F0237 must be purchased to use this remote F0236 RCKIT4001 Standard On Off Remote Control Kit ASH BED MATERIAL Ve...

Page 20: ...________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ __...

Page 21: ...________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ __...

Page 22: ...________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ __...

Page 23: ...l will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the in...

Page 24: ...r name P900579 00 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products...

Reviews: