COMFORT-AIRE REG-123J Owner'S Manual Download Page 8

Owner’s Manual 

Room Air Conditioner with R-410A

 

7

and Fan. The indicator light beside the selected mode will 

illuminate and remain on once the mode is selected.

To operate in Auto feature:

When you set the air conditioner to AUTO mode, it 

will automatically select cooling, heating or fan only 

depending on what temperature you have selected and 

the room temperature.

The air conditioner will control room temperature 

automatically around the temperature set point selected.

To operate in Fan only:

Use this function when cooling is not desired, such as 

for room air circulation or to exhaust stale air (on some 

models). Remember to open the vent during this function, 

but keep it closed during cooling for maximum cooling 

To operate in Dry mode:

In this mode, the air conditioner will generally operate in 

the form of a dehumidifer to remove humidity from the air. 

However, some degree of cooling will continue.

AITONS EQUIPMENT

Summary of Contents for REG-123J

Page 1: ...AITONS EQUIPMENT Guelph ON N1H 6H9 1 888 744 2911 www aitons com REG 81J REG 123J...

Page 2: ...the power cord needs to be replaced replacement work shall be performed by authorized service personnel only Installation work must be performed in accordance with the national and local electric cod...

Page 3: ...a damp environment Do not allow water to run in to electric parts It may cause failure of machine or electric shock Do not use the socket if it is loose or damaged If the power cord is damaged it mus...

Page 4: ...ain power switch when not using the unit for a long time It may cause failure of appliance or accident Do not place obstacles around air inlets or inside of air outlet If bracket is damaged there is c...

Page 5: ...Room Air Conditioner with R 410A Owner s Manual 4 Please refer to the section Operation of Current Device for details AITONS EQUIPMENT...

Page 6: ...may vibrate and make noise because of poor wall or window construction or incorrect installation Pinging or Swishing Droplets of water hitting condenser during normal operation may cause pinging or s...

Page 7: ...e is shifted When the unit is operating in Dry mode the fan speed is automatically controlled at Low fan speed Press or hold either Temp Timer Up or Down button until the desired temperature is seen o...

Page 8: ...ature The air conditioner will control room temperature automatically around the temperature set point selected To operate in Fan only Use this function when cooling is not desired such as for room ai...

Page 9: ...ual 8 AIR CONDITIONER FEATURES CONTINUED TIMER AUTO START STOP FEATURE Press or hold the Temp Timer UP or DOWN button to change the Auto time by 0 5 hour increments up to 10 hours then count down the...

Page 10: ...convert from one to the other press and hold the Left and Right Temp Timer buttons at the same time for 3 seconds 3 3 AIR CONDITIONER FEATURES CONTINUED The 3 way air directional louvers allow you to...

Page 11: ...ps screws Carefully inspect the location where the air conditioner will be installed Be sure it will support the weight of the unit Make sure the air conditioner does not fall and remains upright duri...

Page 12: ...Owner s Manual Room Air Conditioner with R 410A 11 No obstalces blocking air inlets or outlets to 36 91 4 cm max Loosen 1 shipping screw from each side of the cabinet FIG 3 1 AITONS EQUIPMENT...

Page 13: ...Room Air Conditioner with R 410A Owner s Manual 12 1 2 3 4 AITONS EQUIPMENT...

Page 14: ...Owner s Manual Room Air Conditioner with R 410A 13 AITONS EQUIPMENT...

Page 15: ...Room Air Conditioner with R 410A Owner s Manual 14 NOTE Do not block the louvers on the air conditioner cabinet or your unit will not perfrom properly SEE NOTE ABOVE SEE NOTE ABOVE AITONS EQUIPMENT...

Page 16: ...Air Conditioner with R 410A 15 It is recommended to use 1 2 5 cm or thicker lumber for wood frame For through the wall installations if needed install molding not provided around the room side of cabi...

Page 17: ...Room Air Conditioner with R 410A Owner s Manual 16 104 F 40 C AITONS EQUIPMENT...

Page 18: ...Wait approximately 3 minutes for compressor to turn on after time delay when in cool mode Outdoor temp may be below 62 F 17 C To defrost coil set unit to FAN ONLY mode FAN ONLY mode Thermostat set to...

Page 19: ...Room Air Conditioner with R 410A Owner s Manual 18 Solution Problem W Deactivating Prematurely 16 AITONS EQUIPMENT...

Page 20: ...11 201 2020213A1105 1 AITONS EQUIPMENT Guelph ON N1H 6H9 1 888 744 2911 www aitons com...

Reviews: