Technical Service Manual
10
Window slider kit
minimum: 28 /8(72cm)
maximum:55 /8(140cm)
1
3
1
3
Fig. 8.2 Fig .8.3
3. Select the best location
z
Beside the window, door or French window.
z
Keep the distance between the return air outlet and the wall or
other obstacles to at least 20 inches (50cm)
z
Fix one end of the air hose on the air intake or outlet at the back of
the unit.
z
Extend the air hose to the clearance between window, door, or
French window, or wall hole.
z
Air outlet or intake should not be blocked by protective grid or
objects.
z
The distance between two ends of the air hose should be kept at
minimum of 8 inches (200mm)
Note: the cooling capacity will decrease if only the air discharge
hose is used, but air outlet temperature will be lower.
Installation instruction
z
Air outlet or intake opening should not be blocked by curtain, or
other objects.
z
Hose opening should not be block by shutters or other similar
objects.
z
Do not bend the air hose when assembling; keep it straight as
figure 3.
z
When operating in cool or dry mode, condensate will accumulate
in the water tank. When the tank is full, water full indicator will
light up (red) and LCD will display the sign E. The unit will stop
operating.
Shut off the power supply, pull out the rubber plug in drain port at
the rear of the unit, drained the water into a container or other
appropriate area.
Note: water should be drained off when the water full light is on,
otherwise, the appliance will not operate.
Summary of Contents for Comfort-Cire PAD-121
Page 1: ...SERVICE MANUAL PORTABLE ROOM AIR CONDITIONER Models PAD 91 PAD 121 ...
Page 7: ...Technical Service Manual 4 CHAPTER 4 PERFORMANCE CURVES PERFORMANCE CURVE z COOLING UNIT ...
Page 16: ...Technical Service Manual 13 CHAPTER 11 EXPLODED VIEW 1 Exploded View for PAD 91 PAD 121 ...
Page 17: ...Technical Service Manual 14 2 Exploded View for PAD 121 E ...