10. DISMANTLING THE VALVE OR THE COVER

ATTENTION!

The following points must be observed:

- Pressureless pipe system.

- Medium must be cool.

- Plant must be drained.

- Note chapter 3 for proper handling and lifting.

- Additionally, in case of toxic, corrosive, flammable or caustic media:

- Purge pipe system carefully.

- Use proper protection equipment to avoid health harm.

- Adopt proper actions to avoid pollution of the environment.

11. GOODS RETURN & DISPOSAL 

- For any returned goods, the issuing company must provide information in written on any hazards and the precaution in 

case of potentially polluting or harmful residues, or any mechanical damage that could present a health, safety or environ-

mental risk, as enforced by EU Health, Safety and Environment Law, including the Safety Data Sheet of the substances 

identified as potentially hazardous.

- Valves are recyclable and not expected hazard to the environment, with the exception of soft parts (PTFE and rubber 

compounds) that should be disposed separately only by approved procedure, and no incineration is permitted. 

12. WARRANTY / GUARANTEE

- The extent and period of warranty cover are specified in the “General Sales Terms” of COMEVAL VALVE SYSTEMS valid 

at the time of delivery or, by way of departure, in the contract of sale itself.

- We guarantee freedom of faults in compliance with state-of-the-art technology and the confirmed application.

- No warranty claims are accepted for any damage caused as the result of incorrect handling or disregard of this Manual, 

Data Sheet and relevant regulations.

- This warranty also does not cover any damage which occurs during operation under conditions deviating from those laid 

down by specifications or other agreements.

- Justified complaints will be eliminated by repair carried out by us or by a specialist appointed by us.

- No claims will be accepted beyond the scope of this warranty. The right to replacement delivery is excluded.

- The warranty shall not cover maintenance work. 

- Our guarantee coverage does not cover for any commissioning, maintenance or installation of the product or external 

parts.

- Our guarantee does not cover products proved to have been tampered with or faulted by material wear and tear.

- The Purchaser is responsible for checking that the incoming product is received in good condition and  conforms to the 

ordered specifications. In case of damage caused during transit it is necessary to immediately complain to the carrier within 

24 hours. After this time carriers could not assume the derived costs. In case of any deviation in relation to order specifi

-

cations, please contact us.

COMEVAL VALVE SYSTEMS, S.L. y CIA., Soc. Comanditaria

Les Rotes, 15 46540 El Puig

 

(Valencia) España

Phone 

+34 961 479 011 

·

 

Fax 

+34 961 472 799

E-mail 

[email protected] 

-

 www.comeval.es

Summary of Contents for UNIFLOW 3P

Page 1: ...SIBLE DANGERS 2 2 1 Significance of symbols 2 2 2 Explanatory notes on safety information 2 3 PRESERVATION STORAGE HANDLING AND TRANSPORT 2 4 DESCRIPTION 2 4 1 General Description Operating principles 2 4 2 Area of Application 2 4 3 Technical data remarks 2 4 4 Marking nameplate 3 4 5 CE marking 3 5 INSTALLATION 3 5 1 General remarks on installation 3 5 2 Requirements at the place of installation ...

Page 2: ...with Data Sheet and product marking must also be observed and complied with for safely using the product 3 PRESERVATION STORAGE HANDLING AND TRANSPORT ATTENTION Protect against external force impacts vibrations etc Allow only skilled personnel suitable handling and lifting equipment must be used Always use suitable protection equipment and minimize the use of human body force at any step to avoid ...

Page 3: ...r performance Observe all applicable safety measures during installation Remove flange covers or any other remaining packing storage protection if present Lay pipelines such that damaging transverse bending and torsional forces are avoided Protect valves from dirt during construction work The interior of the valve and the pipeline must be free of foreign particles Protect the valve soft parts from...

Page 4: ...quirements at the place of installation Downstream from a disruptive element pump valve elbow pipe reduction leave as much distance as possible mini mum distance recommended 6 times the valve diameter 6xDN Upstream from a disruptive element leave at least a distance of 2xDN Aggressive environmental conditions may reduce the life span of the product Consider special construction protective measures...

Page 5: ...asket and tighten the cover bolts evenly crosswise with moderate and uniform torque Retighten them if leakage is detected under pressure If it is not possible to repair the damages replace the valve and contact us for assistance After any maintenance work please refer to chapters 5 and 6 for installation commissioning Recommended Spare parts Use only original spare parts It is advisable to keep bo...

Page 6: ...ecified in the General Sales Terms of COMEVAL VALVE SYSTEMS valid at the time of delivery or by way of departure in the contract of sale itself We guarantee freedom of faults in compliance with state of the art technology and the confirmed application No warranty claims are accepted for any damage caused as the result of incorrect handling or disregard of this Manual Data Sheet and relevant regula...

Page 7: ...al data contained in this Manual without prior notice Regularly updated data on www comeval es IOM PISTON LIFT DISC CHECK VALVES UNIFLOW 3P 35 Page 7 13 PARTS LIST Nº PART 1 Body 2 Disc 3 Bushing 4 Cover 5 Eye bolt 6 Cover gasket 7 Cover bolt 8 Cover nut 9 Spring option Detailed view with spring option recomended for size 6 and for vertical pipeline UNIFLOW 3P ...

Page 8: ...ny technical data contained in this Manual without prior notice Regularly updated data on www comeval es IOM PISTON LIFT DISC CHECK VALVES UNIFLOW 3P 35 Page 8 14 ANNEXES 14 1 Declaration of Conformity DC20_07EN 14 2 Data Sheet DS20 Updated documents on www comeval es Nº PART 01 Body 02 Disc 04 Cover 06 Cover gasket 08 Cover bolt 09 Spring UNIFLOW 35 ...

Reviews: