Operating instructions – Electromagnetic safety limit switch
010 ISTR 06 SC 0418-00
The product EC declaration is available in the
Download section of the site
DDC 16 – Electromagnetic switches and separate actuator with RFID coding series FEP-RFID
Limits of use
Use the switch in compliance with the standards in force, according to the
instructions and using it according to its limits of operation. In case of improper
use, non-compliance with the instructions, assembly and maintenance carried
out by unauthorized or unskilled staff and failure to perform the functional
tests, the manufacturer is not liable at all. Do not use the device separately to
ensure safety in those areas where the operator can enter with all his body
within the perimeter. Any unintentional closing of the protection behind the
operator could cause dangerous situations for the operator himself. Do not use
in places with continuous changes in temperature, that could cause
condensation inside the device. Do not install in areas with dust or dirt that
could compromise the device operation. Do not install in places with powders
or flammable gases. Do not use outside the temperature limits expected for
operation. Do not use in places where ice sleeves can form on the device or on
the actuator. Do not use with very corrosive chemical agents, that can damage
the internal mechanisms and the device gaskets.
The device complies with the requirements of the following Directives:
Low Voltage Directive 2014/35/EU
According to standard EN 60947-5-1
Machinery Directive 2006/42/EC
According to standard EN ISO 14119
Directive RoHS 2002/95/EC
Certifications
cULus according to standard UL508 – CB according to EN 60947-5-1 – FCC ID
Number 2AP8TCMP9LRF (for the whole list of certified products contact
COMEPI technical support)
Examples of application and operation
This kind of device is usually used to ensure the operator’s safety while using
machines where a dangerous condition can continue even after the machine
is stopped, for instance due to the inertia of mechanical parts that are
moving, or to the presence of warmed up or pressurized parts. If this device is
used separately, it is not suitable for machines where an operator can enter
physically an enclosed area, since the enclosure could close accidentally after
the operator has entered it. To test the correct device operation, check the
right insertion of the actuator into the head slot and close the protection by
starting the machine. In these conditions it must be impossible to open the
protection. On the contrary when the machine is stopped and the protection
is disabled the machine must not start.
Safety warnings
Safety switches protect operators. Any unsuitable installation, as well as the
device tampering and the tampering of the safety system connected to it, can
cause serious dangerous situations. The device must in no way be bypassed or
tampered with. To prevent any easy tampering the installer should assemble
the device in a place difficult to be reached by unauthorized staff, using if
necessary physical obstacles and measures to make it difficult to tamper with
the device.
FCC Part 15 (see recommendations at page 4)
General technical data
Housing
Housing in engineering plastic
Maximum clearance of the locked
actuator
4.1 mm
Room temperature during operation
-20°C … +55°C
Cable inlet
A threaded inlet M20x1.5
Environmental designation
Type-1 enclosure
Prewired version
8-pole M12x1 male connector
Protection against electrical shock
Class II (thermoplastic housing)
Mechanical duration
1 million operations
IP Degree of protection
IP65
B10d
4 million operations
Maximum actuating frequency
600 cycles/hour
Maximum period of use
20 years
Maximum actuating speed
20 m/min
SIL level according to EN 62061
For applications up to SIL3
Weight
0.5 Kg
PL level according to EN ISO 13849-1
For applications up to PLe
Actuation force
5 N
Type of interlock according to EN ISO
14119
Type 4
Extraction force
30 N
Coding level according to EN 14119
High
Maximum holding force Fzh
1200 N
Type of emergency release
Manual
Tensile strength
1560 N
Device supply
24Vcc (+/-10%)
Allowed power supply
Power supply range
Device status
Measures
21.6V < V < 26.4V
Normal operation
None
16.8V < V < 21.6V
26.4V < V > 28V
Alarm mode
LED indication. Adjust as soon as possible the power
supply. The functions continue to be ensured.
V < 16.8V
V > 28V
Device disabled
The device is disabled to avoid dangerous situations
not signalled. Warning: The Electric Lock model
allows reaching immediately the protected area
when there is no power supply.
Solenoid supply
I < 50mA
I > 250mA
Device disabled
The abnormal current on the solenoid can indicate
an incorrect supply or an internal failure. The device
is disabled to avoid any dangerous situation not
signalled.
Warning: The Electric Lock model allows reaching
immediately the protected area when there is no
power supply.
Operating conditions and LED diagnostics
Index
Actuator status
Power supply
Lock control
LED PWR
LED LOCK
LED KEY
Status
21-22 & 41-42
Status A1-A2
COND.01
Key not inserted
21.6V < V < 26.4V
ON or OFF
Red
Off
Off
Open + Open
Open
COND.02
Key inserted and
recognized
21.6V < V < 26.4V
OFF
Red
Off
Green
Open + Open
Closed
COND.03
Key inserted and
recognized
21.6V < V < 26.4V
ON
Red
Red
Green
Closed
Closed
COND.04
Key inserted and not
recognized
21.6V < V < 26.4V
ON or OFF
Red
Off
Red
Open + Open
Open
COND.05
Key inserted and RFID
absence
21.6V < V < 26.4V
OFF
Red
Off
Blinking red
Open + Open
Open
COND.06
Key inserted and
recognized, subsequent
RFID loss
21.6V < V < 26.4V
OFF
Red
Off
Blinking red
Open + Open
Open