background image

 

Operating instructions – Electromagnetic safety limit switch

 

010 ISTR 06 SC 0418-00

 

The product EC declaration is available in the

 Download section of the sit

www.comepi.it

 or contacting the address 

[email protected]

 

DDC 16 – Electromagnetic switches and separate actuator with RFID coding series FEP-RFID 

Limits of use                                                                                                                   
Use the switch in compliance with the standards in force, according to the 
instructions and using it according to its limits of operation. In case of improper 
use, non-compliance with the instructions, assembly and maintenance carried 
out by unauthorized or unskilled staff and failure to perform the functional 
tests, the manufacturer is not liable at all. Do not use the device separately to 
ensure safety in those areas where the operator can enter with all his body 
within the perimeter. Any unintentional closing of the protection behind the 
operator could cause dangerous situations for the operator himself. Do not use 
in places with continuous changes in temperature, that could cause 
condensation inside the device. Do not install in areas with dust or dirt that 
could compromise the device operation. Do not install in places with powders 
or flammable gases. Do not use outside the temperature limits expected for 
operation. Do not use in places where ice sleeves can form on the device or on 
the actuator. Do not use with very corrosive chemical agents, that can damage 
the internal mechanisms and the device gaskets. 

The device complies with the requirements of the following Directives: 
Low Voltage Directive 2014/35/EU 

According to standard EN 60947-5-1 

Machinery Directive 2006/42/EC 

According to standard EN ISO 14119 

Directive RoHS 2002/95/EC 

Certifications 

cULus according to standard UL508 – CB according to EN 60947-5-1 – FCC ID 
Number  2AP8TCMP9LRF  (for  the  whole  list  of  certified  products  contact 
COMEPI technical support) 

Examples of application and operation                                                                       
This kind of device is usually used to ensure the operator’s safety  while using 
machines where a dangerous condition can continue even after the machine 
is stopped, for instance due to the inertia of mechanical parts that are 
moving, or to the presence of warmed up or pressurized parts. If this device is 
used separately, it is not suitable for machines where an operator can enter 
physically an enclosed area, since the enclosure could close accidentally after 
the operator has entered it. To test the correct device operation, check the 
right insertion of the actuator into the head slot and close the protection by 
starting the machine. In these conditions it must be impossible to open the 
protection. On the contrary when the machine is stopped and the protection 
is disabled the machine must not start.    
Safety warnings                                                                             
Safety switches protect operators. Any unsuitable installation, as well as the 
device tampering and the tampering of the safety system connected to it, can 
cause serious dangerous situations. The device must in no way be bypassed or 
tampered with. To prevent any easy tampering the installer should assemble 
the device in a place difficult to be reached by unauthorized staff, using if 
necessary physical obstacles and measures to make it difficult to tamper with 
the device.

FCC Part 15 (see recommendations at page 4) 

General technical data 

Housing  

Housing in engineering plastic 

Maximum clearance of the locked 
actuator 

4.1 mm 

Room temperature during operation 

-20°C … +55°C 

Cable inlet 

A threaded inlet M20x1.5  

Environmental designation 

Type-1 enclosure 

Prewired version 

8-pole M12x1 male connector 

Protection against electrical shock 

Class II (thermoplastic housing) 

Mechanical duration 

1 million operations 

IP Degree of protection 

IP65  

B10d 

4 million operations 

Maximum actuating frequency 

600 cycles/hour 

Maximum period of use  

20 years 

Maximum actuating speed 

20 m/min 

SIL level according to EN 62061 

For applications up to SIL3 

Weight 

0.5 Kg 

PL level according to EN ISO 13849-1 

For applications up to PLe 

Actuation force 

5 N  

Type of interlock according to EN ISO 
14119 

Type 4 

Extraction force 

30 N 

Coding level according to EN 14119 

High 

Maximum holding force Fzh 

1200 N 

Type of emergency release 

Manual 

Tensile strength 

1560 N 

Device supply 

24Vcc (+/-10%) 

 
Allowed power supply 
 

Power supply range 

Device status 

Measures 

 

21.6V < V < 26.4V 

 

Normal operation 

None 

16.8V < V < 21.6V 

26.4V < V > 28V 

Alarm mode 

LED indication. Adjust as soon as possible the power 

supply. The functions continue to be ensured. 

 

V < 16.8V  

V > 28V 

Device disabled 

 

The device is disabled to avoid dangerous situations 

not signalled. Warning: The Electric Lock model 

allows reaching immediately the protected area 

when there is no power supply. 

 

Solenoid supply 

I < 50mA  

I > 250mA 

Device disabled 

 

The abnormal current on the solenoid can indicate 

an incorrect supply or an internal failure. The device 

is disabled to avoid any dangerous situation not 

signalled.  

Warning: The Electric Lock model allows reaching 
immediately the protected area when there is no 

power supply. 

Operating conditions and LED diagnostics 

Index 

Actuator status 

Power supply 

Lock control 

LED PWR 

LED LOCK 

LED KEY 

Status 

21-22 & 41-42

 

Status A1-A2 

COND.01 

Key not inserted 

21.6V < V < 26.4V 

ON or OFF 

Red 

Off 

Off 

Open + Open 

Open 

COND.02 

Key inserted and 

recognized 

21.6V < V < 26.4V 

OFF 

Red

 

Off 

Green 

Open + Open 

Closed 

COND.03 

Key inserted and 

recognized 

21.6V < V < 26.4V 

ON 

Red

 

Red 

Green 

 Closed 

Closed 

COND.04 

Key inserted and not 

recognized 

21.6V < V < 26.4V 

ON or OFF 

Red

 

Off

 

Red 

Open + Open

 

Open 

COND.05 

Key inserted and RFID 

absence 

21.6V < V < 26.4V 

OFF 

Red

 

Off

 

Blinking red 

Open + Open

 

Open 

COND.06 

Key inserted and 

recognized, subsequent  

RFID loss 

21.6V < V < 26.4V 

OFF 

Red

 

Off

 

Blinking red 

Open + Open

 

Open 

Reviews: