Page 1: ...Passion Technology Design EN Simplebus1 Ultra audio module Art UT1010 TECHNICAL MANUAL...

Page 2: ...power cables 230V or higher Safe usage To ensure Comelit products are used safely carefully observe the indications provided in the Manuals Instruction sheets make sure the system created using Comeli...

Page 3: ...module Art UT9270 15 Connection of number keypad module Art UT9279M 16 Programming 17 Configuring the button type to maintain during normal operation single dual 17 Address button modules 17 Program...

Page 4: ...ual indications for disabled individuals assistance request can be activated via programming Facility for 2 call buttons To be finished with cap single button or dual button made using aluminium or pr...

Page 5: ...ip Switches 9 Microphone volume control 10 Programming confirmation button 11 Digital microphone Use screwdriver supplied 12 Terminal block for connection RTE programmable RTE local lock release input...

Page 6: ...f buttons no 2 Backlighting colour White Off Terminals L L V V COM NC NO SE GND RTE TX TX RX RX Number of inputs no 1 Number of outputs no 2 Output type Relay C NO NC 4A 12 24 VAC VDC inrush current 1...

Page 7: ...1 UT9192 UT9194H UT9193 UT9196 UT9199 UT9194 UT9198 Housing frame UT9171 UT9172 UT9174H UT9173 UT9176 UT9179 UT9174 UT9178 Optional The entrance panel is available in flush mounted or surface mounted...

Page 8: ...8 Flush mounted installation 2 1 2 UP 5 3 4 165 cm 130 cm 1 BLACK RED Optional Optional...

Page 9: ...s available to download free of charge from the website pro comelitgroup com The button has a nameplate which can be written on A alternatively an adhesive label can be applied B The total thickness o...

Page 10: ...10 Installation with side by side boxes Before installing the boxes in the wall fit the spacers...

Page 11: ...11 Wall mounted installation 165 cm 130 cm 2 UP 5 3 4 UP 1 2 3 1 Optional BLACK RED Optional...

Page 12: ...DF to print the entrance panel name cards using the adhesive pre cut sheets C available in our catalogue Art UT9110 Custom engraved Full Metal Ultra nameplates are available on request Find out how ht...

Page 13: ...13 Installation with side by side boxes...

Page 14: ...10A MAX AC DC 12V 24V E T R GND SE NO NC C O M L L V V 10A MAX AC DC 12V 24V Connections UT1010 connections Max 20 m Local door opener button C NC NO relay activation on actuator command 2 sec f Set D...

Page 15: ...120 230 V 1595 UT1010 AUDIO DOOR ENTRY SYSTEM RISER E T R GND SE NO NC C O M L L V V 120 230 V 1595 UT9270 UT1010 Module connection Connection of button modules Art UT9200 Connection of Touchscreen m...

Page 16: ...16 AUDIO DOOR ENTRY SYSTEM RISER E T R GND SE NO NC C O M L L V V 120 230 V 1595 UT9279M UT1010 Connection of number keypad module Art UT9279M Max 20 m Local door opener button...

Page 17: ...button modules means that in the event they are replaced it is not necessary to reprogram the button addresses All you need to do is assign the same address as before to the new module II Program cal...

Page 18: ...IP 6 configuring button type Single button DIP6 ON Dual button DIP6 OFF default Set the address of the apartment you wish to call for example 1 using the DIP switches see Addressing table DIP 6 config...

Page 19: ...sh to call for example 25 using the DIP switches see Addressing table S1 S2 8 8 7 6 5 default OFF 8 7 6 5 ON 9 DIP 6 configuring button type Single button DIP6 ON Dual button DIP6 OFF default 25 6 ON...

Page 20: ...6 7 5 8 2 1 4 5 1 Set the dip switches in accordance with the function you wish to program see Special programming table 2 Press the confirm button 7 Reset the configuration of the DIP switches S1 S2...

Page 21: ...ctuator command 4 sec 231 1 2 3 6 7 8 C NC NO relay activation on actuator command 8 sec Door lock 223 1 2 3 4 5 7 8 Door lock command on SE in AC default 224 6 7 8 Door lock command on SE in enhanced...

Page 22: ...tton LEDs on at night and off during the day thanks to the twilight sensor default 161 1 6 8 Enables brightness control for the button LEDs f Press a button repeatedly for each module to change the in...

Page 23: ...he day To change the setting to ON LEDs always on or OFF LEDs always off proceed as follows NOTE when the OFF and AUTO lighting modes are active every time the entrance panel is powered the buttons li...

Page 24: ...nt to check AUTO mode operation for the twilight sensor you can proceed as follows 1 Enter programming mode 2 Block the twilight sensor for 5 seconds If AUTO mode has been set the camera and button LE...

Page 25: ...ting the button brightness Press a button repeatedly for each module to change the individual brightness of the buttons 2 Take note of the DIP switch settings OFF ON 1 2 3 4 6 7 5 8 2 ON 1 2 3 4 6 7 5...

Page 26: ...anks to this function button backlighting is only enabled on the user s request by pressing the LIGHT ME button on the audio video module this saves energy and reduces light pollution Backlighting man...

Page 27: ...ing settings 3 Press the confirm programming button the green lock release LED will start flashing at the end of the backup approx 30 sec the green lock release LED switches off the green audio enable...

Page 28: ...ror Check the position of selectors S1 and S2 they cannot both be set to ON RED LED FLASHING Device in programming All device configurations can be performed via PC and ViP Manager configuration softw...

Page 29: ...2 7 8 224 6 7 8 15 1 2 3 4 45 1 3 4 6 75 1 2 4 7 105 1 4 6 7 135 1 2 3 8 165 1 3 6 8 195 1 2 7 8 225 1 6 7 8 16 5 46 2 3 4 6 76 3 4 7 106 2 4 6 7 136 4 8 166 2 3 6 8 196 3 7 8 226 2 6 7 8 17 1 5 47 1...

Page 30: ...2st edition 06 2021 code 2G40002705 w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy C E R T I F I E D M A N A G E M E N T S Y S T E M S...