background image

9

8

Example of maximum expansion per apartment

1214/2C

1214/2C

Art. 6701W-6701W/8

Art. 6741W

Art. 6801W 

Art. 6721W

Art. 6801W 

Art. 6601W

Art. 6601W

1214/2C

1214/2C

1214/2C

1214/2C

4888C

CV1

CV2

CV1

CV2

1214/2C

6741W

6721W

6721W

6721W

G

CV1

CV2

CV1

CV2

G

A MAX

B MAX

C MAX

D MAX

E MAX

F MAX

G MAX

H MAX

I MAX

Art.1216

Comelit Art. 4577/4579 

1 mm²  

(Ø 1.2 mm AWG 17) 

200 m 

(650 

feet)

200 m 

(650 

feet)

200 m 

(650 

feet)

200 m 

(650 

feet)

150 m 

(490 

feet)

50 m 

(165 

feet)

50 m

(165 feet)

100 m 

(330 

feet)

2

1

UTP5 cat. 5 0.2 mm² 

(Ø 0.5 mm AWG 24) 

80 m 

(260 

feet)

150 m 

(490 

feet)

150 m 

(490 

feet)

150 m 

(490 

feet)

100 m 

(330 

feet)

60 m 

(195 

feet)

2

1

0.28 mm² 

(Ø 0.6 mm AWG 23) 

100 m 

(330 

feet)

150 m 

(490 

feet)

150 m 

(490 

feet)

150 m 

(490 

feet)

100 m 

(330 

feet)

5 m 

(15 feet)

10 m

(30 feet)

60 m 

(195 

feet)

2

1

0.5 mm² 

(Ø 0.8 mm AWG 20) 

120 m 

(395 

feet)

100 m 

(330 

feet)

100 m 

(330 

feet)

100 m 

(330 

feet)

80 m 

(260 

feet)

25 m 

(85 feet)

25 m

(82 feet)

60 m 

(195 

feet)

2

1

1 mm² 

(Ø 1.2 mm AWG 17) 

120 m 

(395 

feet)

150 m 

(490 

feet)

150 m 

(490 

feet)

150 m 

(490 

feet)

80 m 

(260 

feet)

50 m 

(165 

feet)

50 m

(165 feet)

60 m 

(195 

feet)

30 m

(98 feet)

2

1

1 mm² 

(Ø 1.2 mm AWG 17) 

 

120 m 

(395 

feet)

80 m 

(260 

feet)

80 m 

(260 

feet)

80 m 

(260 

feet)

50 m 

(165 

feet)

50 m 

(165 

feet)

50 m 

(165 feet)

40 m 

(130 

feet)

2

1

1.5 mm² 

(Ø 1.4 mm AWG 15) 

150 m 

(490 

feet)

100 m 

(330 

feet)

100 m 

(330 

feet)

100 m 

(330 

feet)

80 m 

(260 

feet)

75 m 

(245 

feet)

100 m

(330 feet)

60 m 

(195 

feet)

50 m

(164 

feet)

2

1

2.5 mm² 

(Ø 1.8 mm AWG 13) 

150 m 

(490 

feet)

100 m 

(330 

feet)

100 m 

(330 

feet)

100 m 

(330 

feet)

80 m 

(260 

feet)

100 m 

(330 

feet)

150 m 

(490 

feet)

60 m 

(195 

feet)

Operating distances

B

A

F

H

1214/2C

1595

1216

6741W

6741W/BM + 6710

4888C

UT1020

S3

DIP 1

I

  Compatible secondary door entry monitors: 6701W (/BM), 6701W/8, 6721W (/BM), 6801W (/BM), 6601W (/BM)

Summary of Contents for Simplebus Color 4888C

Page 1: ...Simplebus 2 Mixer Power Supply Unit Art 4888C EN TECHNICAL MANUAL FREE DOWNLOAD MYCOMELIT L APP PER IL PROFESSIONISTA MYCOMELIT THE APP FOR PROFESSIONALS...

Page 2: ...in the Manuals Instruction sheets supplied with those products Wires Disconnect the power supply before carrying out any operations on the wiring Use wires with a cross section suited to the distances...

Page 3: ...hed cables If it is necessary to run even for short distances sections of cable exiting the mixer Art 4888C section SIMPLEBUS 2 through the same ducting always use separate sheathed cables Do not use...

Page 4: ...DL1 is lit steadily this indicates that the cancellation procedure has been successful 3 Reset JP4 to position 2 factory setting and check that LED DL1 switches off 4888C H 1214 2C 1216 6721W 6721W B...

Page 5: ...t 60 m 195 feet 2 1 0 5 mm 0 8 mm AWG 20 120 m 395 feet 100 m 330 feet 100 m 330 feet 100 m 330 feet 80 m 260 feet 25 m 85 feet 25 m 82 feet 60 m 195 feet 2 1 1 mm 1 2 mm AWG 17 120 m 395 feet 150 m 4...

Page 6: ...UT1020W UT9200 MAX 19 120 230 V 1595 33 Vdc 12VAC VDC 18 MAX 20 m MAX Local door opener button VIDEO ENTRY RISER P L P L S L S L M L M L 1224A 230V L 4 L 2 L 3 L 1 L 2 L 3 L 4 L IN L IN L 1 4888C 4 3...

Page 7: ...ance and to view installation layouts click on the system type that best meets your requirements Simplebus 2 Audio Video with 4888C 20 m MAX Local door opener button Digital Entrance Panel Variant wit...

Reviews: