14
8. TECHNICAL CHARACTERISTICS
Parameter
Condition
Value
Power supply (battery)
3.6V
Protection power supply
inversion
Yes
Inibition time between
alarm
Selectable by dip-switch
3÷6 minutes
Range IR max
Temperature 25 °C
12 m
Range MW max
12 m
Low battery reporting
Selectable by dip-switch
Yes
Range Test
Selectable by dip-switch
Yes
Test run time
3 minutes
Setting IR range
Yes
Setting MW range
Yes
IR °t Autocompensation
Yes
Frequency MW
24,125 GHz
Vertical range MW
80°
Orizzontal range MW
32°
Vertical range IR
90°
Orizzontal range IR
7,5°
Curtain width at 2m / 10m
25cm / 130cm
Warming time
60 s
Operating temperature
-20÷60 °C
IP protection degree
IP54
Gross Weight
131 g
Max dimensions (L x H x P
–mm)
With wall mount bracket
40 x 129 x 48
Max dimensions (L x H x P
–mm)
With angular bracket
45 x 129 x 52