![Comelit RF2PIRB Technical Manual Download Page 5](http://html1.mh-extra.com/html/comelit/rf2pirb/rf2pirb_technical-manual_2639878005.webp)
Dip-switch setting:
DIP 1
ON
active power supply
OFF
non-active power supply
DIP 2
ON
OFF
DIP 3
ON
LED on
OFF
LED off
DIP 4
ON
sensor in OR
OFF
sensor in AND
DIP 5
ON
single impulse
OFF
double impulse
DIP 1
DIP 2 DIP 3 DIP 4
DIP 5
ON
ON
OFF
OFF
OFF
POWER SUPPLY
one 3.6 VDC Lithium battery
CURRENT ABSORPTION
Stand-by condition 20
µ
A – alarm condition 1mA
PULSE COUNT
1 or 2 pulses in 2.5s
LENS TYPE
fresnel
MAXIMUM PIR RANGE
Max 4 m
RADIO RANGE
Max 500 m in open space
ANTIOPENING
internal contact
TEMPERATURE COMPENSATION
automatic
OPERATING TEMPERATURE
-20°C a +50°C
HUMIDITY
85% (max)
DIMENSIONS LXHXD
280 x 38 x 30 mm
WEIGHT
190 gr
GRADE OF PROTECTION
IP54
•
Insert the provided battery in the transmitter and wait about 10 seconds.
•
Make sure that the transceiver is in the learning mode in accordance with instructions from the control panel
programming alarm Comelit.
•
Make a transmission by pressing and releasing the "tamper" switch; This starts the data transmission of "learning" from
the device to the transceiver control panel.
EXAMPLE OF DETECTION AREA
FEATURES
35°
120 cm
50 cm
20
0
cm
FRONT
VIEW
LATERAL
VIEW
EXAMPLE
Recommended
setting
FIRST INSTALLATION
not used
Summary of Contents for RF2PIRB
Page 12: ......