EN
27
4.7 ACTUATOR RELAY MODULE ART. 1256
Intelligent device for controlling a 24 AC/DC 10A relay (fitted) for general uses. Fit a max. of 10 actuator relay modules Art. 1256 on the whole system.
4.7.1 Parts description
1. JP4
2. JP3
3. JP2
To use the actuator relay module with kit HFX-700W
f
Move jumper JP2 to position 2
f
Move jumper JP3 to position 2
f
Move jumper JP4 to position 2
JP1
JP1
JP1
JP1
JP1
JP1
JP2
1
2
JP4
1
2
JP3
1
2
4. S1
DIP switch for different setting
5. JP1
for functions setting
6.
Terminal block for system connection:
NC
relay N.C. contact
COM
relay COM contact
NO
relay NO contact
L L
BUS line input
~+, ~-
power supply input terminals
4.7.2 Functions
Art. 1256 offers the following functions, depending on the position of jumper
JP1
:
• External unit lighting control
• Activation function on Actuator pushbutton.
• Activation function on Actuator with code pushbutton
JP1
JP1
JP1
JP1
JP1
JP1
JP2
1
2
JP4
1
2
JP3
1
2
External unit lighting control
The relay is operated by closing the C.NO. contact in response to a call from an external unit to any address, on internal
ignition from a video entry phone (e.g. to automatically activate lights, CCTV alarm contacts, etc.). The relay closure time
can be programmed using a
S1
DIP-switch, see TAB. B.
JP1
JP1
JP1
JP1
JP1
JP1
JP2
1
2
JP4
1
2
JP3
1
2
Activation function on Actuator pushbutton
The relay is operated by closing the C.NO. contact in response to a Generic actuator call from a video entry phone. The relay
closure time can be programmed using a
S1
DIP-switch, see TAB. B. All Art. 1256 modules set for use with this function are
activated simultaneously when the pushbutton on the internal unit is pressed.
JP1
JP1
JP1
JP1
JP1
JP1
JP2
1
2
JP4
1
2
JP3
1
2
Activation function on Actuator with code pushbutton
The relay is operated by closing the C.NO. contact if the pushbutton pressed on the video entry phone has been programmed
to send the actuator call with the code of the actuator. The closure time of the relay is fixed at 2 sec. To set the user code
by means of a
S1
DIP-switch, see
TAB. B: PROGRAMMING RELAY CLOSURE TIME
(For external unit light function/stair light function, activation function on actuator pushbutton)
DIP switches sur ON
TOUS
1
2
3
4
5
6
7
8
Temps fermeture relais
1’‘
2’‘
4’‘
8’‘
16’‘
32’‘
1’ 5’‘
2’ 10’‘
The relay for Art. 1256 operates in BISTABLE mode, changing its status at every command; if the power supply is cut off, it returns
to the C.NO. position and remains there, even after the power is restored. Bistable mode is available for products with a revision index
equal to or greater than 003.
2.
1.
3.
4.
5.
6.