4.2.3.5 HOW TO PROGRAM THE
AUTOMATIC LOCK-RELASE (DOCTOR MODE)
Example: key
√
Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
Set S2 DIP switch 5-6 to the combination 01
» the Privacy LED flashes
ON
1 2 3 4 6 7
5
8
2
1. Choose the function:
refer to the
S2
DIP switches
combination in which the automatic lock-relase (Doctor Mode) (
D
) is listed for the keys you wish
to program.
2. Addressing:
for Automatic lock-relase
don't set S1 DIP switches
Example: 0110
ON
1 2 3 4 6 7
5
8
Select the key to be associated with the function
Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound.
3
Select the key to be associated with the function
Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound.
4
Exit programming mode
To exit programming mode, set
S2
DIP switches 5-6 to the combination 00
» the Privacy LED switches off
ON
1 2 3 4 6 7
5
8
5
When programming is complete,
Set S2 DIP switches 1-2-3-4 to the combination 1111 (PROG setting). In this DIP switch
setting, the keys control the programmed functions; the NON-programmed keys control
functions referred to on line 0000, see
Restore the user code setting on S1.
ON
1 2 3 4 6 7
5
8
ON
1 2 3 4 6 7
5
8
4.3 RESET PROGRAMMING ART. EX-7000H
Factory settings:
• Button functions for the S2 DIP switch 1-2-3-4 combination;
• Intercom address absent;
• Range function and min./max. addresses absent;
• Ringtone reset.
Take note of the S2, S1 setting and restore it when programming is complete
Carry out steps 1 to 3
1)
2)
3)
DIP OFF
DIP ON
S1
ON
1 2 3 4 6 7
5
8
S2
ON
1 2 3 4 6 7
5
8
5 sec
4.4 RANGE PROGRAMMING ART. EX-7000H
Take note of the S2, S1 setting and restore it when programming is complete
Carry out steps 1 to 4
1)
2)
3)
4)
Range minimum
address
S1
ON
1 2 3 4 6 7
5
8
set code,
25.
S2
ON
1 2 3 4 6 7
5
8
S2
ON
1 2 3 4 6 7
5
8
Range maximum
address