EN
20
4. Additional features programming
4.1 ADDRESSING ART. EX-7000H BY MEANS OF DIP SWITCH
Set the user codes on
S1
DIP Switches as indicated in
4.2 CONFIGURATION CAPACITIVE-TOUCH KEYS ART. EX-7000H
4.2.1 Preset function table
S2
DIP-switches
DIP 1
DIP 2
DIP 3
DIP 4
0
0
0
0
PAG /
ACT
AI
1
0
0
0
NULL
AI
0
1
0
0
INT
AI
1
1
0
0
ACT
NULL
0
0
1
0
ACT
ACT
ACT
1
0
1
0
INT
ACT
0
1
1
0
AI
D
0
0
1
1
PAG
PAG
1
0
1
1
INT
INT
0
1
1
1
NULL
NUL
NULL
NULL
1
1
1
1
PROG
[
] = Default
Legend
AUDIO KEY FUNCTION
AI
SELF ACTIVATION FUNCTION
SILENT MODE (PRIVACY) KEY
INT
INTERCOM CALL
PAG
PAGING FUNCTION
D
AUTOMATIC LOCK-RELASE (DOCTOR MODE)
LOCK-RELEASE FUNCTION
NULL
No function
ACT
ACTUATOR FUNCTION
PROG
Programmed functions:
in this DIP switch setting, the buttons
control the programmed functions; the NON-programmed
buttons control functions referred to on line 0000.
See description functions on page 7.
4.2.2 Quick programming
For the quick programming of the following functions:
• generic actuator (ACT)
• internal intercom calls (INT)
• internal paging calls (PAG)
• self activation main external unit (AI)
• automatic lock-relase (Doctor mode) (D)
1
Set the
S2
DIP switches combination corresponding to the
functions that you want to programme
for
ALL KEYS
as
Example
choose
S2
DIP switches combination:
DIP 1
DIP 2
DIP 3
DIP 4
0
1
0
0
for set all the following function:
PAG /
INT
AI