![Comelit HFX-7000MW Technical Manual Download Page 8](http://html1.mh-extra.com/html/comelit/hfx-7000mw/hfx-7000mw_technical-manual_2640133008.webp)
8
EN
2.3 1209/4 BUS POWER SUPPLY
1. LM LM
Art. 1209/4 connection
2. LS | LS
additional external unit connection
LP | LP
main external unit connection
1. LP LP
external unit connection
2. L1 | L1
monitor connection 1
L2 | L2
monitor connection 2
L3 | L3
monitor connection 3
L4 | L4
monitor connection 4
3.
Video closing jumpers
(REMOVE WHEN LINE IS USED)
4. L N
mains power input 110-240
V~
1.
2.
3.55 in
1.42 in
2.28 in
50-60Hz
OUTPUT/SORTIE 34V 0.5A 2A 1'on/5'off
ta=40°C
110V-240V
1.4A
L
N
L4
L4
L3
L3
INPUT/D'ENTREE
Dopo un cortocircuito,per ripristinare l'apparecchio,
interrompere l'alimentazione per circa 1 minuto.
To reset the operation after a short circuit,cut off mains
voltage for about 1 minute.
Apres un court circuit, pour remettre en fonction l'appareil,
interrompre l'alimentation pendant environs une minute.
L2
L2
L1
L1
LP
LP
C US
R
Art.1209/4
1.
2.
3.
4.
2.4 PARTS IDENTIFICATION FOR EXPANSION
ADDITIONAL INTERNAL UNIT
EX-7000H
EX-7000H
The art.
EX-7000H
is the additional internal unit for Single-User Kits.
(For further information see the respective manual).
ADDITIONAL EXTERNAL UNIT
EX-DSQE
+
1405
EX-DSME
The art.
EX-DSQE
is the additional external unit and contains the
external unit art.
EX-DSME
(See
for further
information)
and the Video door expander art.
1405
further information).
2.4.1 Video door expander 1405
4.17 in
3.52 in
2.44 in