4. Additional features programming
4.1 ADDRESSING ART. EX-7000H BY MEANS OF DIP SWITCH
Set the user codes on
S1
DIP Switches as indicated in
page 30.
4.2 CONFIGURATION CAPACITIVE-TOUCH KEYS ART. EX-7000H
4.2.1 Preset function
DIP
S2
KEY PROGRAMMING
DIP 1
DIP 2
DIP 3
DIP 4
P1
P2
0
0
0
0
PAG /
ACT
AI
1
0
0
0
NULL
AI
0
1
0
0
INT
AI
1
1
0
0
ACT
NULL
0
0
1
0
ACT
ACT
ACT
1
0
1
0
INT
ACT
0
1
1
0
AI
D
0
0
1
1
PAG
PAG
1
0
1
1
INT
INT
0
1
1
1
NULL
NUL
NULL
NULL
1
1
1
1
PROG
default
LEGEND
Lock-release function:
can be used to activate the lock-release relay
Privacy function:
can be used to enable or to disable the ringtone for calls from the external unit and paging.
Audio key function:
can be used to activate a conversation with the external unit or to end a conversation.
ACT
Generic actuator function:
can be used to activate the relay for a generic actuator installed within the system.
Coded actuator function:
can be used to activate the relay for a specific actuator installed within the system.
AI
Self-ignition function:
can be used to receive images from the main external unit cameras (press the key again to cycle through several
external unit)
D
Doctor function:
can be used to enable automatic activation of the lock-release in response to a call from the external unit.
INT
Internal intercom function:
can be used to make a call to the internal units with the same user code.
General intercom to another user code:
can be used to make a call to the internal units with another user code.
PAG
Internal paging function:
can be used to make a paging call to the internal units with the same user code.
General paging to another user code:
can be used to make a paging call to the internal units with another user code.
NULL
No function
PROG
Programmed functions:
in this DIP switch setting, the buttons control the programmed functions; the NON-programmed buttons control
functions referred to on line 0000
4.2.2 Quick programming
For the quick programming of the following functions:
•
generic actuator (ACT),
•
internal intercom calls (INT),
•
internal paging calls (PAG),
•
Self ignition main external unit (AI),
•
Doctor function (D)
1
Set the
S2
DIP switches combination corresponding to the
functions that you want to programme
for
ALL KEYS
as
shown in the
For example
choose
S2
DIP switches combination:
DIP 1
DIP 2
DIP 3
DIP 4
0
1
0
0
for set all the following function:
P1
P2
PAG /
INT
AI