Specifications

 

16 

Input (programmable) 
Outputs: 

- OUT1 
- OUT2 
- OUT3 
Electromechanical relay 
SSR 
MOS gate 
Output for external SSR 
- OUT1 
 
- OUT2 
- OUT3 

Serial Interface 
USB Interface 
Control Algorithm 
Alarms 
Power Supply 
Consumption 
Measurement Error

 

 

Temperature Drift 
Ambient Temperature / Humidity 
Protection / Insulation 

Pt100, 10 T/C types, mA, mV, V, k

 

up to 3 

 alarm AL1, 

 control OUT1 

 none, 

 alarm AL2, 

 control OUT2 

 none, 

 alarm AL3 

5A/250VAC with NO contact 
1A/250VAC  
0.1A/60V, optically isolated  
5...24 VDC, 30 mA  

 relay, 

 SSR, 

 MOS gate, 

 for ext. SSR, 

 0

÷

20 mA, 

 4

÷

20 mA, 

 0

÷

5 V, 

 0

÷

10 V 

 relay, 

 SSR, 

 MOS gate, 

 for ext. SSR 

 relay, 

 SSR, 

 MOS gate, 

 for ext. SSR 

 RS485 with MODBUS RTU/ASCII protocol 

mini-A connector for parameter Read/Write 
PID-fuzzy or ON/OFF 
11 alarm types plus 2 system alarms 
85…265 VAC   
less than 4 VA 

 

±

 0.3% from span 

 

±

 0.01% from span for 1 °C 

0…50 °C / 20…85% RH,  
IP10 / >10 M

 at 500 VDC 

 

 
 

Warranty and Support 

 

…………………………. 

           serial number 

 

…………………………. 

      manufacturing date

 

 

QC check mark …….……(passed)   

(stamp) 

88 Slavyanska Str. 
P.O.Box 378 
Plovdiv 4000, BULGARIA  
tel: +359 32 646523, 646524 
fax: +359 32 634089, 646517 

e-mail: [email protected]      

 

QD-8.2.4-WC

 

 

 

 

 

 

 

Warranty

 

COMECO warrants this product to be free 
from defects in materials and workmanship 
for 2 years. If your unit is found to be 
defective within that time, we will promptly 
repair or replace it. This warranty does not 
cover accidental damage, wear or tear, or 
consequential or incidental loss. This 
warranty does not cover any defects caused  
by wrong transportation, storage, installation, 
or operating (see '

Specifications

').  

Technical support

 

In the unlikely event that you encounter  
a problem with your COMECO device, 
please call your local dealer or contact 
directly our support team. 

 
 

 

 

COMECO Inc., P.O.Box 378, Plovdiv 4000, BULGARIA, tel: +359 32 646523, 646524, fax: 634089  

e-mail: [email protected], WWW.COMECOGROUP.COM 

 

 

 

 

RT1900-R 

 

O PER A T ION  MAN U AL  

 

 

 

 

 

Please read this Operation Manual before mounting and operating! 

Save the Manual for future references!

 

 
 

Communication

 

14 

 

 

 

 

 

 

 

 

 

 

Serial network interface 

If serial interface is installed, 
follow the additional 
requirements given in 
RT1800 Communication 
Manual available from 

www.comeco.org/downloads

 

(Software->Communication 
Prots->Rt1800). 
 

Read/Write parameters 

Regardless of installed serial 
interface, RT1900-R is 
equipped with an independent 
parameter copy system via 
USB interface and IA400 
converter.  
All parameters can be copied, 
saved and transferred to 
other units using 'Parameter 
Copy' free software.  

 

 
 

Error Messaging

 

 

Message  Error type 

in1E 

sensor error  

AdCF 

ADC failure * 

CJCE

 

Input measurement or CJC failure * 

UUU1

 

measured value above high SV limit 
(parameter 

USPL

)

 

nnn1 

measured value below low SV limit 
(parameter 

LSPL

)

 

rAMF 

RAM (memory) failure * 

intF 

interface problem 

AUtF 

unsuccessful auto-tuning 

 

 

 

 

WARNING!

 

When a message marked 
with (*) appears and stays, 
return the unit for repair!

 

 

 
 

Overview 

RT1900-R is a DIN-rail mounting controller with universal input accepting Pt100, 10 
T/C types and various linear signals. It can have up to 3 relays (control or alarm) and 
analog output that may be controlled through ON/OFF and self-tuning PID-fuzzy 
algorithms as well as optional RAMP/SOAK pattern control. A bumpless auto-manual 
change-over is also built in the PID algorithm. RT1900-R is equipped with 4-digit LED 
display and 4-button keyboard for programming. A triple input/output/supply isolation 
protects the controller from electro-magnetic disturbances. Communication features 
include RS485 MODEBUS interface and USB port for program parameter storage. 
RT1900-R is well equipped for trouble-free operation in harsh industrial conditions. 

 

 
 

Mounting 

 

 

 

  

 

RT1900-R can be mounted on 
every 33-mm rail confirming EN 
50022. 

 

Install RT1900-R following the 
steps 1-2 as shown on the left. 

 

Always observe device 
dimensions (W40xH107xD43) 
before installation!  

 

 

Uninstall Rt1900-R using a 
suitable screwdriver and 
following the steps 1-2 as 
shown on the left picture. 

 
 
 
 

 

If install 2 or more units on the 
same rail, use the enclosed 
plastic spacer to provide 
adequate air cooling distance 
following the marks on the left.  

 

Never place units without a 

gap (min. 5mm) between them or 
other rail-mounted devices!  
It may result in overheating and 
device failure!

 

 

UNIVERSAL PID CONTROLLER

 

v

1

-0

9

.1

2

 

Summary of Contents for RT1900-R

Page 1: ...nstalled follow the additional requirements given in RT1800 Communication Manual available from www comeco org downloads Software Communication Prots Rt1800 Read Write parameters Regardless of installed serial interface RT1900 R is equipped with an independent parameter copy system via USB interface and IA400 converter All parameters can be copied saved and transferred to other units using Paramet...

Page 2: ...eated and recycled in accordance with the laws of your jurisdiction implementing the WEEE Directive 2002 96 on the Waste Electrical and Electronic Equipment Wiring 4 Gently remove transparent plastic protectors from terminal blocks prior wiring Install the protectors again when finish Input signal wiring Connect Pt100 sensors to terminals 9 10 and 11 or T C sensors to terminals 9 and 10 Connect li...

Page 3: ...2 fixing pins 2 from their slots 3 and then open the cover 1 rotating it up Find the input jumper located on the right side of the terminal Place the jumper bridge in UP position for T C or in DOWN position for Pt100 input Programming procedure First go to Level 2 and set LC to 0000 From Level 1 User level press SET keys for 5s to enter Level 3 Set input type by selecting it from Table 1 For analo...

Page 4: ...SET GAP2 0 SET LC 0000 SET Return to P1 Programming procedure From Level 1 User level press SET key for 5s to enter Level 2 Set PID proportional band for OUT1 0 0 to 200 0 0 0 converts PID to ON OFF Set PID integral time for OUT1 0 to 3600 s 0 converts PID to PD Set PID derivative time for OUT1 0 to 900 s 0 converts PID to PI Set dead band time for OUT1 do not care let stay 0 Set auto tuning offse...