Connecting The Stations

Connections between the telephone stations and the common equipment station boards are typically via type
66M-xx connector blocks that are cable connected to 50-pin male connectors on the station boards.

The maximum distance allowed from the common equipment to the industry-standard telephone varies with the
gauge of wire that you use to make the connection. Refer to the following chart for complete details.

Station Type

Wire Gauge

20 AWG

22 AWG

24 AWG

Industry-Standard

Telephones

4000 Feet

3500 Feet

3000 Feet

The maximum distances stated above are dependent upon the following conditions:

resistance of industry-standard telephone (per EIA specs) cannot exceed 300 ohms maximum,

DC load resistance of the wiring between the common equipment and the industry-standard telephone plus
the DC resistance of telephone itself cannot exceed 460 ohms maximum.

If spare conductors exist in the cables that you run between the station boards and the 66M-xx connector blocks, it
is a good practice to connect the spare conductors to earth ground. Doing this may help prevent the spare
connectors from inducing radio frequency and/or AC interference into the system.

Remember, you should snap a ferrite collar around each station cable to provide protection against radio
frequency interference.

NOTE: The polarity between the individual wires in a particular voice pair is not critical.

8 – Installing The IST Board

IMI89–268

Installing The IST Station Board

Summary of Contents for FXIST-08

Page 1: ...Besides the onboard DTMF receivers that some boards provide the auxiliary board accepts optional DTMF receiver cards up to three cards per board and the Interface board accepts one optional receiver card Each receiver card allows four ISTs to dial simultaneously The overall number of DTMF receivers you need to install depends upon how active the ISTs will be at the site See the section titled Dete...

Page 2: ... MAUX provides 8 onboard DTMF receivers and the FXAUX2 16 provides 16 onboard DTMF receivers Further you can add up to three DTMF receiver cards to any auxiliary board to provide an additional 12 DTMF receivers over any onboard support provided by the Auxiliary board or add one DTMF card to the Interface board However adding these cards prevents you from adding other option cards such as communica...

Page 3: ...es Simultaneous Dialing Telephones Complying With Underwriters Laboratories Regulations Per The Underwriters Laboratories regulation be aware of the following precautions when installing telephone equipment that is to be directly connected to the telephone company network Never install telephone wiring during a lightning storm Never install telephone jacks in wet locations unless the jack is speci...

Page 4: ...al battery back up assembly before you remove or install the circuit board However if the board does include a pre charge port you can connect a standard telephone handset cord between the pre charge port on the circuit board and the pre charge port on the power supply assembly FXS and remove or install the circuit board while the system is operating On FXT systems the pre charge cord is pre wired...

Page 5: ...talling The IST Station Board IMI89 268 Typical Earth Ground Static Wrist Strap ESD Protective Mat ESD Protective Mat ESD Protective Worksurface Static 2 Common Point Ground Creating A Static Safe Work Area Typical Earth Ground Static Wrist Strap ESD Protective Mat ESD Protective Mat ESD Protective Worksurface Static 2 Common Point Ground Creating A Static Safe Work Area Typical Earth Ground Stati...

Page 6: ...rom it s static protection bag until you are ready to install it Conversely when you remove a station board from the cabinet immediately place it in a static protection bag 4 Locate the proper board slot on Impact FX systems the station boards connect to any universal slot 5 If you are removing or installing the station board in an operating system connect the free end of the pre charge cord to th...

Page 7: ...Installing The IST Board 7 Installing The IST Station Board IMI89 268 screws2 cdr Locating Board Hardware remove cdr Removing And Installing Circuit Boards ...

Page 8: ...industry standard telephone per EIA specs cannot exceed 300 ohms maximum DC load resistance of the wiring between the common equipment and the industry standard telephone plus the DC resistance of telephone itself cannot exceed 460 ohms maximum If spare conductors exist in the cables that you run between the station boards and the 66M xx connector blocks it is a good practice to connect the spare ...

Page 9: ... connector block Punch down the station wiring on the 66M xx connector block Route the house wiring for the stations from the station termination to individual station jacks typically 625A 4 modular wall jacks 6 5 4 3 2 1 TI RI R2 T2 GREEN RED Front View Of Jack 1 No Connection 2 No Connection 3 Ring 1 Red Wire Voice 4 Tip 1 Green Wire Voice 5 No Connection 6 No Connection Station Site station cdr...

Page 10: ...ath Green 9 Brown Red 9 18 Red Red Slate 10 35 19 Signal Path Yellow 10 Slate Red 10 20 Black Black Blue 11 36 21 Signal Path Green 11 Blue Black 11 22 Red Black Orange 12 37 23 Signal Path Yellow 12 Orange Black 12 24 Black Black Green 13 38 25 Signal Path Green 13 Green Black 13 26 Red Black Brown 14 39 27 Signal Path Yellow 14 Brown Black 14 28 Black Black Slate 15 40 29 Signal Path Green 15 Sl...

Page 11: ... requires 24 timing circuits In the Impact FX each universal slot provides 32 timing circuits Because of this timing circuit provision of each slot you can place any station or line board at any slot location with no restrictions Adding boards without renumbering If you install or relocate a station or line board this board does not operate until you take appropriate programming action If you use ...

Page 12: ... each installed telephone with a DC voltmeter Then call the industry standard telephone to stimulate the ring generator assembly and measure the AC ringing voltage across the Tip and Ring leads for each installed telephone with an AC voltmeter The measured voltages must be within the limits shown in the chart below If your measured readings are different from these charted values it could indicate...

Reviews: