Signal Pin
Function
1
Voltage set-point input, analog return
14
Voltage set-point input, analog positive
2
Current limit set-point input, analog return
15
Current limit set-point input, analog positive
3
Output voltage monitor, analog positive
16
Center tap terminal voltage monitor, analog positive
4
Positive terminal current monitor, analog positive
17
Negative terminal current monitor, analog positive
5
Monitor circuits, analog return
18
HV enable input, positive input
6
HV enable, negative input
19
Polarity change command, input positive
7
Polarity change, input negative
20
Discharge command, input positive
8
Discharge command, input negative
21
HV indicator output, open collector
9
HV indicator output, open emitter
22
No connection
10
No connection
23
No connection
11
No connection
24
+15Vdc
12
+15Vdc
25
Control circuit common ground
13
Control circuit common ground
Addendum for ESC-2/FP - 2KV Systems.
Front Panel Display—Scaling:
1.
Voltage setpoint and monitor scaling: The voltage setpoint and ouput monitor displays read at full scale
as 2.00, this implies an output of 2000 volts dc from HV+ to HV- terminal. The scaling is linear throughout
its entire range. Thus, .10 represents 100vdc and .05 is 50vdc output.
2.
Current setpoint and monitor scaling: The current setpoint and I+ and I- ouput monitor displays read at
full scale as 3.0, this implies an output of 3mA dc from either HV+ to HV- terminal. The scaling is linear
throughout its entire range. Thus, .1 represents .1mA dc.
9
Certification
1.
This unit carries the ETL safety compliance mark to UL standard UL-1012.
2.
This unit is designed and labeled in compliance with CE mark certification requirements. The
manufacturer will supply a Declaration of Conformity as required.
© 2006 Comdel, Inc.