background image

Micro-Abrasive Blasting Workstations

 

Comco Inc. 

Page 2 

Issue Date: July 2016

 

Operation and Service 

 

The Comco WS2200 and WS6000 series WorkStations are designed for use with all Comco 
series micro-abrasive blasters.  Each workstation provides a generous work chamber 
illuminated by two fluorescent tubes.  The work chamber has a large tempered glass viewing 
window that is hinged to facilitate loading and unloading of parts.  Two 5" arm holes with 
flexible rubber iris baffles permit access so that an operator may hold work with one hand 
and a nozzle handpiece with the other.  The workstation has a 4" dust exhaust connection at 
the rear so that a high capacity dust collection unit may be used to keep the abrasive dust 
completely controlled. 
 
The Comco WS2200 and WS6000 WorkStations are designed to work as part of a micro-
abrasive blasting system consisting of the following: 
 

1. The 

workstation 

2.  Pressurized air (gas) 
3.  An air filter-dryer 
4.  A dust collection unit 
5.  A micro-abrasive blaster (AccuFlo

®

. MicroBlaster

®

, PowerFlo

®

, or DirectFlo™) 

 

Micro-Abrasive Blaster 

 

 

The micro-abrasive blaster is the heart of the blasting system.  The manual that 

comes with your blaster will cover in detail the system requirements and operation.  
Refer to that manual for more information regarding preparation, set-up, operation 
and maintenance of your micro-abrasive blasting system. 

 

Dust Collection Unit 

 

 An industrial type dust collector is necessary to provide adequate air flow to 
evacuate spent abrasive particles from the workstation.  Typically the dust collector 
should be capable of providing 350 to 500 scfm of air flow through the workstation.  If 
the dust collection unit delivers lower volumes of air, it will not be able to remove the 
heavier, coarser abrasives and will diminish the operator's visibility in the workstation. 

 

The Comco Warranty

 

 
Comco warrants that the workstation will be free from all defects in material and 
workmanship under normal use for a period of one year from the date of purchase or 2,000 
hours of normal operation, whichever comes first. Contact Comco Inc. for complete details 
and exclusions regarding this warranty. 
 
 

Summary of Contents for WS2200 Series

Page 1: ...16 This manual covers all variations of the Comco WS2200 and WS6000 series WorkStations WS2200 1 WS2280 2 WS6000 2 etc Comco Inc 2151 N Lincoln Street Burbank California 91504 USA Phone 818 841 5500 FAX 818 955 8365 www comcoinc com E mail tech comcoinc com Book P N WS2019 File WS Manual doc ...

Page 2: ... 5 A micro abrasive blaster AccuFlo MicroBlaster PowerFlo or DirectFlo Micro Abrasive Blaster The micro abrasive blaster is the heart of the blasting system The manual that comes with your blaster will cover in detail the system requirements and operation Refer to that manual for more information regarding preparation set up operation and maintenance of your micro abrasive blasting system Dust Col...

Page 3: ...ctricity Flammable powders such as wheat starch walnut shell and plastic may pose a fire or explosion hazard Some powders if allowed to collect inside the machine may cause electrical shorts If sensitive to powder or dust on the skin wear gloves in the workstation Workstation Set Up and Operation Installation 1 Remove the workstation from its shipping container and place it securely on a solid wor...

Page 4: ...Fluorescent lamps burned out Powder build up in lamp bracket preventing electrical contact Ballast failed Switch failed Dust builds up inside 1 Remove old lamps 2 Replace lamps commercial items 1 Unplug unit 2 Remove lamps 3 Use brush to clean out bracket 4 Reinstall lamps 5 Plug in unit and test 1 Remove lamps 2 Turn Power switch to ON 3 Using voltmeter test for voltage across lamp bracket termin...

Page 5: ...Comco Workstations Wiring Diagrams Comco Inc Page 5 Issue Date July 2016 WS2200 Series Classic WorkStation 115 or 230V WS6000 Series ClearView WorkStation 115 or 230V ...

Page 6: ...5311 2 ST5311 2 5 Iris 5 2 WS6006 WS6006 WS6006 6 Switch ST7003 ST7003 ST7977 7 Ballast 115 230V ST7997 1 ST7997 1 ST7997 1 8 Lamp 3 ST7164 ST7164 3 ST7164 4 9 Mat WS1136 WS2255 2 WS6007 10 Tube Grip Bulkhead 4 ST5640 3 ST5640 3 ST5640 3 1 Workstations with 5 8 dia holes in panels use Grommet P N ST5311 2 Older workstations S N below 4460 use 4 Iris P N WS2028 1 3 Standard replacement lamps are av...