Installation and 

Operator Manual  

    

 

        

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for 621 Series

Page 1: ...ComCo Systems Inc 800 533 3794 www comcosystems com 500648 Rev A 621 Series Pharmacy Installation and Operator Manual ...

Page 2: ...copyright No part of this publication may be reproduced in any form or used as the basis for the sale or manufacture of apparatus without prior written consent by ComCo Systems 2020 ComCo Systems INC All rights reserved Some of the materials and applications described in this publication may be protected under one or more of the following US patents DES272076 4180354 4971481 4984939 5584613 603951...

Page 3: ...21 Manual Operator Unit pg 4 Operations Specification 621 Customer Unit pg 8 Operations Specification Dual Blowers pg 11 Operations Specification Carriers pg 13 Operations Specification Theory of Operation pg 14 Installation pg 16 System Setup and Installation Field Wiring Diagram Maintenance and Cleaning pg 23 Troubleshooting pg 24 Replacement Parts pg 25 Contents ...

Page 4: ... located near the teller unit The Model 621 is configured with three major subsystems 1 621 Operator Unit P N 201314 2 Dual Blower Unit P N 200281 3 3 621 Customer Unit P N 201315 Features Operator Unit TU 621 201314 Manual operated door unit which is suspended from the ceiling typically over countertop Customer Unit CU 621 201315 Open carrier access design with optional 2 way video unit Dual Pack...

Page 5: ...ComCo Systems Inc 800 533 3794 www comcosystems com 500648 Rev A 4 621 Series Operator Unit Model TU 621 201314 ...

Page 6: ...nit s door MUST remain closed during a send or recall cycle for the system to function properly The operator unit door should only be opened when a carrier is being inserted to send to the customer unit or immediately after a carrier has arrived from the customer unit To resume operation close door and press RECALL or SEND Please note the reference guide in Fig 1 0 Operation Fig 1 0 ...

Page 7: ...m Inside Unit Outside Unit Blowers Power ON all lights will be present Power OFF complete system power down SEND Sends a carrier to the customer unit The operator unit door must be closed in order to send a carrier to the customer unit RECALL Recalls a carrier from the customer unit The operator unit door must be closed in order to recall a carrier from the customer unit Operation ...

Page 8: ...ev A 621 Series Operator Unit P N 201314 Dimensional Electrical Specifications Item Measurements Value Operator Unit TU 621 200430 1 Nominal Voltage Current max 24 VAC From Blower 1 Amp System Controller P N 200155K See Appendix A For System Settings Specification ...

Page 9: ...ComCo Systems Inc 800 533 3794 www comcosystems com 500648 Rev A 8 621 Series Customer Unit Model CU 621 201315 ...

Page 10: ...com 500648 Rev A 621 Series Customer Unit P N 201315 Machine Switch Operating Instructions SEND Sends carrier to Teller Unit CALL Generates audible tone at the Pharmacy when depressed Bottom Switch Plate P N 201328 Top Switch Plate P N 201327 Operation ...

Page 11: ...0 621 Series Customer Unit P N 201315 Dimensional Electrical Specifications Item Measurements Value Customer Video Module CVM 2000 200903 10 Nominal Voltage Current max 12 VDC 3 5 Amps 1520 Lane Station 600651 Nominal Voltage Current max 12 VDC 1 5 Amps Specification ...

Page 12: ...11 ComCo Systems Inc 800 533 3794 www comcosystems com 500648 Rev A 621 Series Dual Pack Blower Model 200217 2 x2 ...

Page 13: ...Line Power must be done in compliance with the NEC National Electrical Code by authorized qualified personnel 2 115 VAC 0 5 A Resettable Fuse 2 115 VAC 1 5 A Resettable Fuse Class 2 Field Wiring SHOCK HAZARD Disconnect AC Power before Servicing Unit AC Service Disconnect for Unit is located at the Main Junction Breaker Box Use minimum hardware to mount unit in place For mounting location see cut s...

Page 14: ...ransmission tubing or possibly lose their contents during transmission If coins are to be sent it is recommended that they be rolled and placed in a pouch or bag Loads that can shift during transmission may cause malfunction or damage to the carrier or system Carriers are not to exceed a gross weight of 5lbs The contents of the carrier must be fully within the carrier and not caught between edges ...

Page 15: ...indicator extinguishes 3 System is now off The power switch may be used to recover from unusual system conditions simply by switching it off and on this will reset the system Send cycle 1 Technician inserts carrier into Operator Unit 2 Technician closes Operator Unit door and presses SEND 3 Send cycle begins 4 Pressure blower activates 5 The valve in the Operator Unit Check Valve closes and the va...

Page 16: ... the Operator Unit Check Valve opens sending vacuum to the Customer Unit 6 Carrier is pulled from Customer Unit into transmission tubing towards Operator Unit 7 Carrier passes Operator Check Valve 8 Carrier is decelerated by pressure ahead of carrier valve in Check Valve blocks pressure from Operator Unit 9 Carrier arrives at Operator Unit 10 Cycle timer times out 11 Recall cycle ends system is no...

Page 17: ...ComCo Systems Inc 800 533 3794 www comcosystems com 500648 Rev A 16 621 Series Cut Sheets NOTE Installation ...

Page 18: ...17 ComCo Systems Inc 800 533 3794 www comcosystems com 500648 Rev A 621 Series Cut Sheets NOTE Installation ...

Page 19: ...ComCo Systems Inc 800 533 3794 www comcosystems com 500648 Rev A 18 621 Series Cut Sheets NOTE Installation ...

Page 20: ...19 ComCo Systems Inc 800 533 3794 www comcosystems com 500648 Rev A 621 Series Field Wiring Diagram D N 5006 NOTE Deceleration switches MUST be wired in Parallel Installation ...

Page 21: ...ComCo Systems Inc 800 533 3794 www comcosystems com 500648 Rev A 20 621 Series Control Audio Field Wiring Diagram D N 500073 NOTE Refer to Audio Authority Manual for Audio Installation Installation ...

Page 22: ...21 ComCo Systems Inc 800 533 3794 www comcosystems com 500648 Rev A 621 Series System Riser Diagram Options Parts Descriptions Installation ...

Page 23: ...bing All tubing must be sealed properly Seal all joints especially those at the teller and customer units All inside edges of tube joints must be de burred and ground to an angle to prevent excessive wear on carriers Timer Adjustment Adjust timer T1 for approximately 5 seconds greater than the time required for an empty carrier to be recalled from the customer unit to the teller unit this should b...

Page 24: ...regularly usually every 3 6 months depending on usage Customer Unit Operator The carrier deceleration switches are required for proper operation If they are inoperable the carrier will land hard at the customer unit Cleaning Carriers The carrier is to be cleaned with alcohol wipes containing no more than 75 Isopropyl Alcohol Customer Unit Operator The Operator and Customer unit are to be cleaned w...

Page 25: ...n be tested individually by connecting a 9v battery to pins 3 and 4 of Solid State Relay To replace blower motors see video link below Blower Replacement Video Carrier Arrives Hard at Customer Unit Verify carriers are in good condition Ensure that the solenoid is engaging at end of cycle Check that I7 LED is turning on at end of cycle Refer to Appendix A for LED details Troubleshooting Low Voltage...

Page 26: ... 1 Control Board 200155K 1 Door Handle Assembly 201140 1 Brass Keeper 400178 1 Door Assembly 200027 1 1 Membrane Valve for Receiver Box 401468 1 Membrane Valve for Check Valve 400116 1 1 621 Customer Unit Description Part Number Usage per Lane Upper Switch Plate 201327 1 Lower Switch Plate 201328 1 Rubber Bumpers 605204 2 Microphone Assembly 200746 1 Speaker Assembly 200067 1 Main Harness 200665 1...

Page 27: ... Interface Board 200717 2 Dual Blower Interface Harness 200748 1 Solid State Relay 609819 4 Transformer Assembly 201170 2 5 Amp Circuit Breaker 604414 2 1 5 Amp Circuit Breaker 604435 2 10 Amp Circuit Breaker 604412 4 Solenoid Assembly 200282 2 Carriers Description Part Number Usage per Lane 6 Single End Opening Carrier 602124 1 Misc Description Part Number Usage per Lane Deceleration Switch 20059...