background image

(CR0687740) 7

Burners, Thermocouples, Ignition electrodes

• Remove the lower and upper front panel, drawer, cast iron
grills, splashguard , burner tiles, and replace the component.

Gas tap, Piezo igniter

• Remove the lower and upper front panel and replace the
component.

USE AND MAINTENANCE INSTRUCTIONS

WARNINGS

Do not store flammable materials in or near the appliance. Do
not spray aerosols in the vicinity of this appliance while it is
in operation.

Beware of the appliance’s hot surfaces! 

This appliance is designed for professional use and must only
be used by trained personnel. It is exclusively designed to
cook food. Any other use is considered improper.
If the appliance breaks down, close the gas shut-off valve
upstream of the appliance and call the technical assistance
service.
Repairs should only be carried out by authorised service
centres.

For service and spares parts, please contact Comcater 1800
810 161.
The manufacture declines any responsibility if these
obligations are not respected.

Read this manual carefully and keep in a safe place.
Before using the appliance, thoroughly clean all surfaces that
may come into contact with food.

USE

Positioning the cast iron grills

The cooking grill can be positioned in two ways depending
on the type of cooking and characteristics of food to be
cooked.
- horizontal position : suitable for slow cooking
- inclined position    : suitable for normal cooking

Fat drainage drawers

• Fat that falls from the cast iron grill during cooking passes
through the tiles to be collected in a special drawers. While
using the appliance , empty them when they are nearly full.
• For better cooking results and to facilitate cleaning at the
end of the day, pour 2-3 cm of water into each grease
collection drawer.

Use of the grill

The gas tap control knob has the following positions:

Ɣ

Off
Pilot ignition

maximum cooking temperature
minimum cooking temperature

Turning on the burners

• Press the knob in and turn to the position “ Pilot ignition “.
• Press the knob fully in and press the piezo igniter button to
light the pilot flame. Hold the knob pressed in for approx. 20
seconds, then release it. If the pilot flame goes out, repeat the
operation
Make sure the pilot burner is lit by checking the flame
through the inspection hole in upper front panel.
• Turn the knob to the desired cooking temperature.

Turning off the burners

• To switch off the main burner, turn knob to position “ Pilot
ignition “.
• To switch off the pilot burner, turn knob to position “Off”.

CARE AND MAINTENANCE

• Do not wash the appliance with jets of water.
• Before cleaning the appliance, disconnect from the electric
power supply (if connected).
• Clean stainless steel surfaces daily using water and non-
abrasive detergents. Rinse thoroughly and dry.
• Do not use steel wool pads or chlorine-based products.
• Do not use corrosive substances to clean the floor
underneath the appliance.
• If the appliance is to remain idle for a long period, close the
gas shut-off cock upstream of the appliance and clean
thoroughly.
• The appliance should be inspected and the gas exhaust pipe
cleaned by an authorised service engineer at least twice a
year.
For this purpose we recommend taking out a service contract.

SPARE PARTS LIST

• Main burner
• Pilot burner
• Thermocouple
• Ignition electrode
• Gas tap
• Piezo igniter
• Tiles

Summary of Contents for ANG9.G

Page 1: ...IONS FOR INSTALLATION ADJUSTMENT USE AND MAINTENANCE page 2 4 APPENDIX pagina 5 6 Read the manual thoroughly and keep it in a safe place throughout the product s service life Read the warning notes immediately DOC NO CR0687740 0805 ...

Page 2: ...INSTALLATION DIAGRAM SERIE 90 Mod ANG9 G Measurements in cm Key G Attacco arrivo gas Gasanschluß Gas connection Arrivée Union de gasUNIISO 7 1 R3 4 CR0687740 1 ...

Page 3: ...1 JOINING APPLIANCES TOGHETHER IN LINE 2 ...

Page 4: ...FIG 2 MAIN BURNER PILOT BURNER FIG 3 GAS VALVE TAP 3 ...

Page 5: ...ATURAL GAS PROPANE NATURAL GAS PROPANE NATURAL GAS PROPANE 30 41 00 39 6 T1 INJIECTOR OREFICES SIZES MM A MM MARKING T2 BURNER AERATION SHUTTERS SETTING CR0687740 4 MM 18 MJ h 1 13 2 75 kPa T3 NOMINAL GAS CONSUMPTION T4 MAXIMUM GAS INLET PRESSURE 1 00 2 50 T5 NOMINAL TEST POINT PRESSURE VALUES VALUES SHOWN ARE THOSE MEASURED AT THE MANIFOLD PRESSURE TEST POINT kPa ...

Page 6: ...OCEDURE 5 Testing the gas system Testing the nominal thermal power Setting the manifold gas pressure TROUBLESHOOTING GUIDE 5 The pilot burner is difficult or impossible to ignite The pilot burner goes out during use The main burner is difficult or impossible to ignite REPLACEMENT OF SPARE PARTS 5 Burners Thermocouples Ignition electrodes Gas tap Piezo igniter USE AND MAINTENANCE INSTRUCTIONS 6 WAR...

Page 7: ...ferent gas supply follow the instructions below Use the injectors contained in the bag supplied with the appliance Replacement of burner injector and adjustment of burner air flow Fig 2 Remove the upper front panel and drawer Unscrew the existing injector U and replace it with the one indicated in Table T1 in Technical Data section Position the air regulator at the distance A indicated in Table T2...

Page 8: ...s While using the appliance empty them when they are nearly full For better cooking results and to facilitate cleaning at the end of the day pour 2 3 cm of water into each grease collection drawer Use of the grill The gas tap control knob has the following positions Ɣ Off Pilot ignition maximum cooking temperature minimum cooking temperature Turning on the burners Press the knob in and turn to the...

Reviews: