10
TECHNICAL DATA
Model
Classfication
of anti-
electic
shock
Capacity
(L)
Effective
Volume
(
L
)
Net
Weight
(kg)
Overall
Dimension of
model with D
(mm)
Overall
Dimension of
model without D
(mm)
I
136
103
47
564*712*1155
564*694*850
I
151
105
48
564*737*1138
584*694*850
I
235
170
52
800*712*1143
800*694*850
I
236
170
52
800*712*1190
800*694*902
I
270
178
55
944*712*1125
944*694*850
I
271
179
55
944*737*1125
944*694*850
I
280
220
64
949*712*1190
949*694*902
7455.2010
I
325
240
65
1044*712*1143 1044*694*850
I
352
280
68
1225*671*1195 1225*649*905
I
360
244
69
1204*712*1125 1204*694*850
I
361
251
69
1204*737*1125 1204*694*850
7455.2015
I
405
300
71
1240*712*1143 1240*694*850
I
406
300
72
1240*712*1212 1240*694*922
I
505
375
78
1510*737*1125 1510*694*850
I
511
335
85
1510*737*1125 1510*694*850
I
516
395
80
1510*712*1212 1510*694*922
I
517
395
80
1510*712*1212 1510*694*922
I
575
430
90
1684*712*1143 1684*694*850
I
587
450
112
1800*694*1212 1800*694*922
I
616
485
108
1800*712*1212 1800*694*922
I
620
485
108
1800*712*1212 1800*694*922
TROUBLE SHOOTING
TROUBLES
REASON
SOLUTION
Unfreezing
*Temperature control is on the highest point
Adjust the temperature
*Plug and outlet not connected well
Make the two connect well
*Fuse broken off
Change the fuse
Compressor
cannot stop
working
*Temperature control is on the lowest point
Adjust temperature control
*Too much stuff stored in one time
Reduce the quantity
*Thick frost
Defrost
*Too much times of door-opening
Reduce the times of door-opening
*Too near the wall
Far from the wall
*Near the hot source or sun
Change the place
Big noise
*Ground is not flat
Change the place
*Refrigerating tubes connected
Separate them
REMARK: If you cannot solve the troubles according to the above-mentioned ways, please contact the
after-sale service, do not handle it yourself
.