By default, the EXT ALMs work with Normally Open dry contact alarm wiring; the dry contact alarm type
(Normally Open or Normally Closed) can be configured using the WEBOMT tool. The two wires from dry
contact alarms can be tied to EXT ALMs positive and negative termination block – the polarity does not
matter.
5.
Install AC input wires
Primary Lead / Earthing Lead: min. 14 AWG (cable is not included)
6.
Install wires for load
BBU provides 3 sets of terminations for loads
All 3 loads share the same power being supplied by the charger or batteries
Note: All Comba BDAs, MUs, RUs, and other -48V products come with a power cable.