USER MANUAL FOR COMFLEX-6900
ENU STATUS : 1-0-0
Copyright - refer to title page
Page 62
Table 13: RU Alarm List
Alarm List
Alarm Condition
External Alarm
Alarm status when the external terminals have the same H/L level with alarm
level, otherwise normal;
Alarm period: 10s by default.
Over-Temperature
Alarm
Alarm when equipment temperature is higher than the threshold, otherwise
normal;
Alarm judgment period: 3 minutes by default;
Alarm threshold : 80
℃
by default.
Optical Tx Alarm
Alarm When optical transmiting power is lower than the threshold, otherwise
normal;
Alarm judgment period: 3 minutes by default;
Alarm threshold: 0dBm by default.
Optical Rx Alarm
Alarm When optical receiving power is lower than the threshold, otherwise
normal;
Alarm judgment period: 3 minutes by default;
Alarm threshold: -14dBm by default.
PA Alarm
Alarm when any one of the PA Current Alarm,PA Over-temperature Alarm,
PA DL output power overload Alarm, Reflection Power Alarm happens,
otherwise normal;
Alarm judgment period: 3 minutes by default.
DL Output
Overload Alarm
Alarm when the DL output power is higher than the threshold, otherwise
normal;
Alarm judgment period: 3 minutes by default;
Alarm threshold: 48dBm.
Shutdown Alarm
Alarm when the PA status is off, otherwise normal;
Alarm judgment period: 10s by default.
LNA Alarm
Alarm when LNA have problems, otherwise normal;
Alarm judgment period: 3 minutes by default.
6.2 TROUBLESHOOTING
Following installation and commissioning, occasional operation tasks to handle alarms may be required:
Table 14: MU Alarms Diagnosis
Alarm condition
Diagnosis
Over-
Temperature
alarm
Check device temperature on WEB GUI
If device temperature is over threshold, make sure environment temperature
is within the envireonment temperature range that MU supported (0~40
℃
).
Apply climatic protection to the system under severe environment.
Optical TX Alarm
Test MU transmit optical power
Replace FOU if transmit optical power is less than -7dBm
Optical RX Alarm
Use Optical Power Meter to test received optical power
If received optical power is lower than -10dBm, test whether RU transmit
optical power is normal (3~5dBm)
Check if optical loss of fiber link is higher than 6.5dBo
Clean fiber connector with absolute ethanol
DL Input Power
Overload Alarm
Test DL input power of MU, if it is higher than +33dBm, choose proper coupler to
ensure the input power to MU is lower than +33dBm.