DISPLAY OF THE HEAD

Pictogram

Meaning

Action

Starting of the head

Wait a few seconds

Update of the head

Wait for 1 to 2 minutes

Low battery level

Remember to change the batteries

Critical battery level, the 

heads doesn't control the 

temperature anymore.

Change the batteries to recover the head 

functionnalities

Communication problem

1.  Disconnect and reconnect the internet box 

gateway. The two lights on the gateway should be 

green and steady.

2.  If the gateway has both lights fixed after the 

restart and the head continues to display these 

pictograms, contact customer service.

Radio range limit

Your thermostatic head is at the limit of radio range, a 

repeater may be necessary, contact customer service.

The calibration is 

inconsistent

1. Remove the head from the radiator.

2. Remove the batteries for 30s and reinsert them.

3.  Observe if the head piston makes a back and forth 

movement.If Yes: Remove the batteries. - remount the 

head. - Reinsert the batteries to restart the calibration. 

- If the error persists, contact customer service. 

If No: contact the customer service

The radiator valve has not 

been detected during the 

calibration.

1.  Make sure that the head is properly installed on the 

thermostatic body (Tightening, no clearance)

2.  Restart the calibration by removing the batteries for 

10s and putting them back in.

3.  If the problem persists, contact customer service.

or

or

or

Summary of Contents for L150003001

Page 1: ...Connected heating solution Connected head Installation manual ...

Page 2: ... is compatible with the heads diameter M28 or M30 thread 1 5 mm The 30 mm diameter adaptable heads are also compatible with Danfoss RA thermostatic inserts and bodies adapter included in the universal pack Handle the head with care Keep good air circulation near the head Do not cover the COMAP head Caution ...

Page 3: ...arthome com 3 Follow the installation procedure online step by step Visit the page app comapsmarthome com Download the COMAP Smart Home app and start the installation of your product Create your accout in the app ...

Page 4: ...e in mm Check the thermostatic valve on your radiatorbeforeinstallationtoseeifitiscompatiblewiththemodelyouhave purchased The thermostatic heads They are generally graduated from 1 to 5 and can be easily replaced by a COMAP Smart Home head The manual valves If some of your radiators have manual valves we advise you to go through a licensed installer to make your valve compatible with the COMAP Sma...

Page 5: ... heads ref L150005001 L150006001 L150007001 depending on the thermostatic valve installed on your radiator 2 COMAP thermostatic heads 1 gateway according to the reference you purchased see page 12 4 AA LR6 batteries 1 ethernet cable 1 USB cable 2 M30 M28 adapters 2 Danfoss adapters KIT CONTENT ...

Page 6: ... box The heads communicate with the gateway by radio waves 868MHz The maximumdistancebetweenthegatewayandtheheadsdependsonthestructure of your house wall thickness materials and the radio environment Description of the head Gateway Temperature sensor LED Display Handwheel to change the setpoint Piston Mounting nut Head Head ...

Page 7: ...o range limit Your thermostatic head is at the limit of radio range a repeater may be necessary contact customer service The calibration is inconsistent 1 Remove the head from the radiator 2 Remove the batteries for 30s and reinsert them 3 Observe if the head piston makes a back and forth movement If Yes Remove the batteries remount the head Reinsert the batteries to restart the calibration If the...

Page 8: ...tion 2 Create your account on the application Follow the steps to create an ac count on your COMAP Smart Home application 3 Connect the gateway to your internet box The first light power light on the gateway lights up The second light on the gateway communication light lights up and flashes then becomes steady after 1 to 2 minutes ...

Page 9: ...ead 8 The other heads automatically appear in the application as they communicate 9 Once the heads are set up in the application proceed with the assembly of the heads 9 19 5 5 Place the heads within 40cm of the gateway 6 Turn the ring to wake up each head next to the gateway 4 Insert the batteries into the head a Slide the handwheel forward b Insert the batteries in the direction indicated in the...

Page 10: ...use it is too big screw on the adapter M30 M28 if you have a universal kit 11 If necessary add an adapter 10 Remove the current head If your insert or thermostatic body is of the Danfoss RA type separate the two plastic parts of the adapter Screw the Danfoss adapter corresponding to your model onto the radiator tube 10 ...

Page 11: ...d COMAP in the right direction 14 Put the battery in the head and slide the handwheel sideways being careful to place the double groove of the handwheel on the lower part of the head The head will calibrate on your valve Screw the metal ring clockwise until the head is fixed to the radiator Tighten with a wrench ...

Page 12: ...01 2 heads M30 1 gateway 1 USB cable 1 RJ45 cable 4 AA LR6 batteries L151008001 L150003001 2 heads M30 2 M30 M28 adapters 2 Danfoss RA adapters 1 gateway 1 USB cable 1 RJ45 cable 4 AA LR6 batteries L150005001 1 head M28 2 AA LR6 batteries L150006001 1 head M30 2 AA LR6 batteries L150007001 1 head M30 1 M30 M28 adapters 1 Danfoss RA adapters 2 AA LR6 batteries ...

Page 13: ...120 g without batteries Gateway 55g without cables Design Design 5 5 Studio Design LED screen Warranty 2 years Warnings The programmable thermostatic head is for indoor use only The unit must be installed in accordance with current standards Batteries must be clean before being inserted into the unit Keep children away from the batteries If swallowed consult a doctor immediately Do not attempt to ...

Page 14: ...Version Janvier2022 FAQ https support qivivobycomap com Email contact comapsmarthome com ...

Reviews: