ID-Mobile Global Guide
192
Related FW
2.6.0
Related applications
AMF, MRS
Comm object
47
Description
Charger fail detection. D+ output current is limited to cca 300 mA.
Guaranteed level for signal Charging OK = 90% of supply voltage.
There are three possible conditions for stop engine cranking: Starting RPM, StartingPOil and D+ (when
ENABLED). Starter goes off when any of these conditions becames valid.
ChrgAlternFail
Related FW
2.6.0
Related applications
AMF, MRS
Comm object
321
Description
Indication of active Load - blocking.
Load Blocking
Related FW
2.6.0
Related applications
AMF, MRS
Comm object
371
Description
Communication with Master control unit fails.
MasterCommErr
Related FW
2.6.0
Related applications
AMF, MRS
Comm object
54
Description
The lubrication cycle (PrelubrTime) is not finished after controller Switch on or return from OFF mode.
Not Lubricated
Related FW
2.6.0
Related applications
AMF, MRS
Comm object
313
Description
Active overload protection activation.
Overload