InteliDrive DCU Marine - 3.0.0 Global Guide
209
Related FW
3.0.0
Related applications
All
Comm object
274
Description
Inverted function to binary output Idle/Nominal. The output closes during engine start, after Idle Time
setpoint elapses. The output closes again after Cooling Time is finished.
Nominal/Idle
Related FW
3.0.0
Related applications
All
Comm object
275
Description
Function is based on Binary output Common Alarm - stays closed when any alarm is active (at least one
item in Alarm list) and opens for 2 sec when any new Alarm is activated. The first activation is delayed 2 sec.
No Fault reset influence when at least one alarm is active. Output opens when Alarm list is empty.
Alarm Blink
Related FW
3.0.0
Related applications
All
Comm object
276
Description
The output is closed when setpoint Basic setting: Idle/Nominal = NOMINAL or Idle/Nominal = BIN.INPUT
and corresponding Binary input BI Nominal is closed. This logical output (Source) can be configured to
corresponding J1939 output (e.g. Idle Speed Select in Volvo-IndustrialD12 Aux).
Idle Sw
Related FW
3.0.0
Related applications
All
Comm object
26
Description
Constant value that can be configured to any output (e.g. CurrentGear in Volvo-PRP).
Logical 0
Related FW
3.0.0
Related applications
All
Comm object
27
Description
Constant value that can be configured to any output (e.g. CurrentGear in Volvo-PRP).
Logical 1
Summary of Contents for InteliDrive DCU Marine
Page 29: ...InteliDrive DCU Marine 3 0 0 Global Guide 29 Protection delay and blocking ...
Page 51: ...InteliDrive DCU Marine 3 0 0 Global Guide 51 4 2 2 Electronic engine without redundancy line ...
Page 255: ...InteliDrive DCU Marine 3 0 0 Global Guide 255 Analog inputs from J1939 configuration ...
Page 265: ...InteliDrive DCU Marine 3 0 0 Global Guide 265 Engine Values ...
Page 285: ...InteliDrive DCU Marine 3 0 0 Global Guide 285 6 back to Appendix 6 back to Table of contents ...