InteliDrive DCU Marine - 3.0.0 Global Guide
183
Related FW
3.0.0
Related applications
All
Comm object
159
Description
If input is active and Logical Analog input Requested RPM is not valid (out of range, sensor fail),
Loadsharing: ThrottlePos is set to Load sharing: Back Up Speed value. Loadsharing: ThrottlePos = 0,0%
when analog request is out of range and Binary input Back Up Speed is not active.
Back Up Speed
Related FW
3.0.0
Related applications
PRP
Comm object
158
Description
Remote engine start with cranking attempts according to setpoint Engine params Crank Attempts.
RemRepStart (PRP only)
Related FW
3.0.0
Related applications
All
Comm object
160
Description
If active, clutch is disconnected and Loadsharing: ThrottlePos is set to Engine params: FireAlarmSpeed, the
ThrottlePos value change is influenced by ramp specified by Loadsharing: RQSP Ramp.
Fire Speed
Related FW
3.0.0
Related applications
PRP
Comm object
183
Description
If active closes binary output Clutch Connect – see
Rem Clutch
Related FW
3.0.0
Related applications
All
Comm object
68
Description
OR logical function of all StartBlocking Logical Binary inputs forces controller NotReady state ( i.e. disables
engine start). It is active in LOC (Local) mode as well.
StartBlocking1
Summary of Contents for InteliDrive DCU Marine
Page 29: ...InteliDrive DCU Marine 3 0 0 Global Guide 29 Protection delay and blocking ...
Page 51: ...InteliDrive DCU Marine 3 0 0 Global Guide 51 4 2 2 Electronic engine without redundancy line ...
Page 255: ...InteliDrive DCU Marine 3 0 0 Global Guide 255 Analog inputs from J1939 configuration ...
Page 265: ...InteliDrive DCU Marine 3 0 0 Global Guide 265 Engine Values ...
Page 285: ...InteliDrive DCU Marine 3 0 0 Global Guide 285 6 back to Appendix 6 back to Table of contents ...