InteliDrive DCU Marine - 3.0.0 Global Guide
115
Setpoint group
Basic settings
Related FW
3.0.0
Range [units]
1 .. 10 [-]
Default value
1
Step
1
Comm object
15794
Related applications
All
Config level
Standard
Setpoint visibility
Always
Description
RHS Index (RHS means Running Hours Souce ) is index of ECU module, which is used as source of engine
running hours.
RHS Index
Setpoint group
Basic settings
Related FW
3.0.0
Range [units]
0 .. 250 [min]
Default value
0
Step
1
Comm object
10121
Related applications
All
Config level
Standard
Setpoint visibility
Always
Description
Timeout for ID display backlight automatic switch off. Zero setting disables display backlight switch off.
Backlight is automatically switched on after any key press or Alarm activation.
Note:
LightTimerOff
setpoint influences the Remote panel not master controller when changed on
Remote panel.
LightTimeOff
Setpoint group
Basic settings
Related FW
3.0.0
Range [units]
[hh:mm:ss]
Default value
0:00:00
Step
[-]
Comm object
10042
Related applications
All
Config level
Standard
Setpoint visibility
Always
Description
See
description.
Timer ON
Summary of Contents for InteliDrive DCU Marine
Page 29: ...InteliDrive DCU Marine 3 0 0 Global Guide 29 Protection delay and blocking ...
Page 51: ...InteliDrive DCU Marine 3 0 0 Global Guide 51 4 2 2 Electronic engine without redundancy line ...
Page 255: ...InteliDrive DCU Marine 3 0 0 Global Guide 255 Analog inputs from J1939 configuration ...
Page 265: ...InteliDrive DCU Marine 3 0 0 Global Guide 265 Engine Values ...
Page 285: ...InteliDrive DCU Marine 3 0 0 Global Guide 285 6 back to Appendix 6 back to Table of contents ...