Page 6 of 24
INSTRUCTION MANUAL
ISN T8
IMPEDANCE STABILIZATION NETWORK (ISN)
1912 1 E l T o ro R d
●
Si l vera do, Ca lifo rni a 9 26 76
●
(9 49) 459 -96 00
●
co m-p o wer. com
REV080515
2.4
ISN Calibration Kit
Com-Power’s ISN Calibration Kit provides all of the needed calibration
adapters/accessories. Also provided are detailed, step-by-step
instructions to intuitively guide you through the calibration of the following
electrical parameters:
9
Impedance -
[asymmetric - common-mode]
9
Phase
[asymmetric - common-mode]
9
Voltage Division Factor (VDF)
9
Decoupling Attenuation (Isolation)
9
Longitudinal Conversion Loss (LCL)
Generally, any of the folliowing combinations of test & measurement
equipment may be employed for the calibration:
Network Analyzer with [2-port] S-parameter capabilities
Spectrum Analyzer or EMI Receiver with Tracking Generator,
and Impedance Analyzer (or equivalent)
Spectrum Analyzer or EMI Receiver,
Synthesized Signal Generator,
and Impedance Analyzer (or equivalent)
Gain-Phase Analyzer with Impedance measurement capabilities
The ISN calibration kit is available with the following items:
Part Description
Part Number
Balance Transformer (LCL Probe)
ISN-BT-T248
Balance Transformer Calibration Load Block
ISN-CLB-BT
(2x) 10 dB Attenuators
ATTN-10-T248
(2x) 150
Ω
to 50
Ω
Adapters
ADA-515-T248
BNC Short Adapter
ADA-0-BNC
BNC 50
Ω
Terminator
BNC-50-BNC
8 cm Twisted Pair with 1mm banana plugs
ISN-CBL-1mm
(2x) RJ
45
(or RJ
11
) Common Mode Adapter
ISN-ADA-T248-RJ
xx
(4x) 1x100
Ω
Pair Termination for LCL Adapter w/1mm
ISN-100x1-T248-1mm
4x100
Ω
Termination Block for Conn. Adapter w/1mm
ISN-100x4-T8-1mm
Adapters/Terminations for LCL measurement of individual pairs
Single Pair
RJ
11
or
RJ
45
Two Pairs
RJ
11
or
RJ
45
Three or Four Pairs
RJ
45
Part Number
for
Pair Adapter or
100
Ω
AE Terminator
P1
100
Ω
P1
P2
100
Ω
P1
P2
P3
P4
100
Ω
ISN-T2-
xxx
-RJ
yy
X
X
ISN-T4-
xxx
-RJ
yy
X X X
ISN-T8-
xxx
-RJ
yy
X X X X X