Model CDN -AF4
4.0 Establishing a drive table
Before you begin you will need to test your setup to establish
the correct immunity levels. The setup is similar to the
attenuation measurment setup except connect the power
amplifier to the CDN input (please see figure 2-5). The 1EC-
1000-4-6 call out testing to three different open circuit test levels.
The table below shows unmodulated disturbing signal levels
expressed in r.m.s.
Figure 2-5 Level measurement setup using CDN
Table 2-2 Test Levels specified by IEC-1000-4-6
2-4
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12345678901234567890123456789012123456789012345678901234567890
12345678901234567890123456789012123456789012345678901234567890
EUT
AE
INPUT
150
Ω
- 50
Ω
Adapter
Calibration Jig with shorting bars
SIGNAL GENERATOR
SPECTRUM ANALYZER
DIRECTIONAL
COUPLER
POWER AMPLIFIER
POWER METER
POWER ATTENUATOR
6 dB
CDN
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
150
Ω
- 50
Ω
Adapter
50
Ω
Adapter