7
Water Full Indicator:
When the water pump is full of water, the indicator light turns
on to remind the user to drain.
Purge Button:
Press to empty water from the condensate pump reservoir. Use
"PURGE" before moving the dehumidifier to avoid water spillage. During normal
operation, the pump purges automatically when the reservoir is full. The FULL
indicator will light up after you pressed the PURGE button, which means the pump is
working. 30 seconds later, the pump will stop working automatically and the FULL
light will go off.
Timer Button:
The TIMER function enables you to either Delay Start or Delay Stop
the dehumidifier in the choice from 1 hour to 24 hours.
If the dehumidifier is running, then selecting Timer will turn the dehumidifier off in
the hours that will be set (Delay Stop). If the dehumidifier is off, then selecting Timer
will turn the dehumidifier on in the hours that will be set (Delay Start).
To Set Timer:
1) Press and hold the TIMER button for 3-5 seconds;
2) Adjust the timer setting by pressing the TIMER button to change the delay timer
at 1-hour increments, up to 24 hours. The control will count down the time
remaining (8,7.5,7, etc.) until the dehumidifier either starts or stops.
3) After TIMER setting finishes, pressing the TIMER button again at any time will stop
the TIMER function.
Note:
- The Delay Start/Stop Feature will work until the dehumidifier either starts or stops.
Once that happens the above steps have to be repeated.
- The TIMER feature is one-shot. So the timer will not cycle the dehumidifier on or off
indefinitely.
- Before entering the TIMER setting, make sure you
’
ve plugged it in.