11
1. Erection
Place Test Rig to appropriate location and
fasten the frame to the ground.
2. Assembly of the hollow hydraulic cylinder
• Take out the cylinder from packing material.
• Take off the hexagon nuts (1) from the
threaded rod (5) and pull out the threaded
rod out of the hollow cylinder.
• Place the cylinder (2) onto the steel plate (4)
of the frame and fasten the cylinder by use
of the two attached screws at the bottom.
Coupler (3) must schow to pump tabel side.
• Place threaded rod (4) from below through
the steel plate (4) and hollow cylinder (2)
and lock the rod with the two hexagon nuts
(1)
at appropriate location.
Make sure that the shakle block (6) can move
at least 200 mm to the top.
Counterlock the two nuts (1).
3. Assembly of the hand pump.
• Take out the preassembled hand pump (8)
plus "pressure set unit" from packing material
carefully.
• Place hand pump on pump table and fasten
the pump by use of the attached screws.
• Connect hydraulic hose by coupling the male
coupler half into the female counter part (3)
completely (!), fasten the sleeve nut handtight.
• Fasten hydraulic hose to frame by means of
the attached clamp (7).
• Put one of the attached pressure gauges into
the female coupler half of the
pressure set unit.
Test rig is now ready for use.
Please note the separate operating instructions
for RPYS-1215.
2
8
6
5
1
3
4
7
Operating Instructions for
Hydraulic Test Rig 12 tons Model: RPYS-1215