LaserGuard Mini Technical Manual
July 2021
3 Mechanical Installation
3.1 Mounting Location Considerations
Ensure the mounting location is as far as possible from exposed trolley wires and sources of
electromagnetic or radiated noise.
If possible, avoid installation on a surface where high vibration or shock exists. If avoiding high vibration or
shock is not possible, use appropriate shock mounts.
3.2 Laser Dimensions
Figure 3-1: Laser Sensor (P/N: LGM-HEAD) Dimensions (mm)
CAUTION
The LaserGuard Mini Systems are not rated as explosion-proof. Never install the unit in explosive
environments unless taking appropriate secondary enclosure measures.