24
INSTALLER/SERVICEMAN
Model Number
LVD-75
LVD-100
LVD-110
Burner Type
Riello
Riello
Riello
Burner Model
BF5
BF5
BF5
Nozzle Type
.65 60W
.85 60W
.90 60W
Pump Pressure PSI
150
150
150
Head/Pin Position
2.0
2.0
2.0
Air Band
N/A
N/A
N/A
Air Shutter
3.25
4.25
4.5
Draft Over Fire
0 to +.10" 0 to +.10" 0 to +.10"
Draft In Stack
-0.02"
-0.02"
-0.02"
CO2 Reading
10-11.5% 10-11.5% 10-11.5%
Smoke Reading
ZERO
ZERO
ZERO
NOTICE
Above settings are approximate. Final adjustments to be made
with proper test equipment. Be sure all oil lines are air free and
the use of flare fittings is recommended. See installation/ser-
vice manual for detailed information.
________________________
________________________
________________________
________________________
________________________
________________________
________________________
________________________
________________________
________________________
INSTALLER/SERVICEMAN
Model Number
LV-75
LV-100
LV-110
Burner Type
Beckett
Beckett
Beckett
Burner Model
NX
NX
NX
Nozzle Type
.60 60°B
.75 60°B
.85 60°B
Pump Pressure PSI
175
175
175
Head/Pin Position
2.5
3.5
4.0
Air Band
N/A
N/A
N/A
Air Shutter
N/A
N/A
N/A
Draft Over Fire
+0.000"
+0.050"
+0.080"
Draft In Stack
-0.020"
-0.020"
-0.020"
CO2 Reading
10-11.5% 10-11.5% 10-11.5%
Smoke Reading
ZERO
ZERO
ZERO
NOTICE
Above settings are approximate. Final adjustments to be made
with proper test equipment. Be sure all oil lines are air free and
the use of flare fittings is recommended. See installation/ser-
vice manual for detailed information.
________________________
________________________
________________________
________________________
________________________
________________________
________________________
________________________
________________________
________________________
INSTALLER/SERVICEMAN
Model Number
LVD-75
LVD-100
LVD-110
Burner Type
Carlin*
Carlin*
Carlin*
Burner Model
EZ-1
EZ-1
EZ-1
Nozzle Type
.65 60°A
.85 60°A
.90 60°A
Pump Pressure PSI
140
140
140
Head/Pin Position
0.75
0.85-1.00 1.10-1.25
Air Band
0.50
0.85
0.75
Air Shutter
N/A
N/A
N/A
Draft Over Fire
0 to +.1"
0 to +.1"
0 to +.1"
Draft In Stack
-0.02"
-0.02"
-0.02"
CO2 Reading
10-11.5% 10-11.5% 10-11.5%
Smoke Reading
ZERO
ZERO
ZERO
*Requires Carlin Air Intake Adapter
NOTICE
Above settings are approximate. Final adjustments to be made
with proper test equipment. Be sure all oil lines are air free and
the use of flare fittings is recommended. See installation/ser-
vice manual for detailed information.
________________________
________________________
________________________
________________________
________________________
________________________
________________________
________________________
________________________
________________________
INSTALLER/SERVICEMAN
Model Number
LVD-75
LVD-100
LVD-110
Burner Type
Beckett
Beckett
Beckett
Burner Model
AFII
AFII
AFII
Nozzle Type
.65 70B
.85 70B
.90 70B
Pump Pressure PSI
140
140
140
Head/Pin Position
0
0
3
Air Band
2.0
3.75
4.5
Air Shutter
N/A
N/A
N/A
Draft Over Fire
0 to +.1"
0 to +.1"
0 to +.1"
Draft In Stack
-0.02"
-0.02"
-0.02"
CO2 Reading
10-11.5% 10-11.5% 10-11.5%
Smoke Reading
ZERO
ZERO
ZERO
NOTICE
Above settings are approximate. Final adjustments to be made
with proper test equipment. Be sure all oil lines are air free and
the use of flare fittings is recommended. See installation/ser-
vice manual for detailed information.
________________________
________________________
________________________
________________________
________________________
________________________
________________________
________________________
________________________
________________________