2
HANDS-FREE FLOOR MOUNTED SCRUB SINK
COLUMBIA SPECIFICATIONS MODEL 532F1
1622 Browning Irvine, CA 92606-4809 Phone: 949.474.0777 Toll Free: 800.626.2117 Fax: 949.474.1191
www.columbiasinks.com
email: info@
columbiasinks.com
©2015 Columbia Products
Tools Required
Tape Measure
Adjustable Wrench
Drill Motor and Drill Bits
Pipe Wrench
Level
Safety Glasses
Screw Drivers: 1 Phillips & 1 Standard
Pencil
Socket Wrench
Parts List
(1) Floor mount sink - Model 531F1
(1) Leg assembly set
(4) Washers and nuts for connection sink to leg assembly set
(1) Single foot pedal valves (bottom mount) with mounting nuts - Model 106L
(1) Swivel gooseneck spout with aerator - Model 2003L
(1) Strainer assembly with basket - Model 1011
(1) Connecting tube for valve to spout connection - Model 1007L
(2) Fittings, brass, 0.375” male compression and 0.375” male NPT - Model 1008L
(1) Mixing check valve - Model 201L
Installation Instructions
Step 1
1. Attach upper and lower leg support brackets to legs with hardware (provided).
2. Place wash station sink on leg assembly and secure with hardware (provided).
3. Establish sink location.
4. Mark the floor where the four holes are at the base as shown in illustration A.
5. Drill holes as required for mounting hardware. (Hardware not included).
Step 2
1. Install spout assembly to the sink.
2. Install elbow fitting (provided) to the spout assembly.
3. Connect one side of the supply line (provided) to the spout assembly.
4. Install strainer assembly.
Step 3
1. Install mixing check valve and elbow fitting to valve.
2. Install foot pedal valves under the leg assembly cross bar if not mounted already.
3. Attach connecting tube from the spout to the foot pedal valve.
Step 4
1. Secure wash station to floor.
2. Connect waste line to strainer assembly.
3. Connect water supplies (hot and cold) to the mixing check valve.
Step 5
1. Remove aerator from the spout assembly and flush water line by pressing pedal for 30
seconds.
2. Check connections for leaks. Replace aerator onto the spout assembly.
3. Seal gap between bowl and leg assembly as shown in illustration B.
4. When mounting against wall, we recommend sealing top of backsplash to wall as shown in
illustration C.
Illustration A
Illustration B
Illustration C