background image

Summary of Contents for MiniPar 54

Page 1: ......

Page 2: ...annel protocol Macros Master Slave mode DMX PRIMER Understanding DMX Assigning a start address Grouping fixtures Understanding controller and fixture channels Troubleshooting Warranty Returns Maintena...

Page 3: ...ixture may need warranty work you will need to return it in the original box Do not discard the box and packing material for this reason Failure to ship the fixture back in its proper packaging can po...

Page 4: ...no need for an external controller Equipped with a lighted 4 digit LCD control panel you can easily make changes to DMX addressing or access internal programs The MiniPar 54 s polymer housing is scrat...

Page 5: ...persons can handle or manipulate the fixtures Make sure the mounting surface or truss can adequately support the fixture prior to mounting This fixture must have a secondary safety device installed s...

Page 6: ...plugs into the fixture 2 In connector and so on Always use a DMX terminator on the last fixture in the chain Controller In Out In Out In Out Out Fixture 1 Fixture 3 Fixture 4 Fixture 2 DMX terminator...

Page 7: ...motors etc Do not allow kinks or excessive twisting to occur in the cable Do not split a DMX chain with a Y Splitter use an optical isolated DMX splitter only Do not connect more than 16 fixtures with...

Page 8: ...our controller s polarity switch is not set correctly Refer to the operation manual of your controller for more information about this issue 1 3 2 1 3 2 COMMON DMX DMX DMX Terminator 120 Ohm 1 4 watt...

Page 9: ...A512 MODE VALUE rL rL00 rL12 GL00 GL12 GL bL00 bL12 bL FL00 FL12 FLAS FA00 FA12 FADE AS00 AS12 ASC SOUND ACTIVATE 3 COLOR SOU1 SO 1 SOUND ACTIVATE 7 COLOR SOU2 SO 2 Control Panel Use this mode to set...

Page 10: ...are set to 0 bL BLUE DIMMER static color mixing Use this mode to set the intensity of the blue LEDs for static color mixing To enter this mode press MENU then press UP or DOWN until you see bL press...

Page 11: ...e response from the fixture Bass frequencies offer the best results To enter this mode press MENU then press UP or DOWN until you see SO 1 press ESC The display will now read SOU1 There are no value s...

Page 12: ...ode such as FADE for example Then set all other fixtures to SLA mode then press ESC The master fixture will now control all other fixtures in sync Make sure the master does not have a controller conne...

Page 13: ...ress 001 does not have to be the first in line it can be anywhere in the chain You can also assign the same start address to multiple fixtures called Grouping Fixtures This will allow those fixtures t...

Page 14: ...up to 12 fixtures max 16 x 12 192 This means each fixture button on the controller can control up to 16 channels within a given fixture Lighting fixtures also have channels referred to as fixture cha...

Page 15: ...unused unused unused Fixture 2 Moving Head Start Address 017 Ch 17 Ch 18 Ch 19 Ch 20 Ch 21 Ch 22 Ch 23 Ch 24 Ch 25 Ch 26 Ch 27 Ch 28 Ch 29 Ch 30 Ch 31 Ch 32 FIXTURE CHANNELS CONTROLLER 16 CHANNELS Wit...

Page 16: ...data cable only The last fixture in a chain should always have a DMX terminator Never use a Y splitter always use an Optical DMX Splitter see Cabling tips Use fewer than 16 fixtures or add a Optical...

Page 17: ...or shock dents etc evidence of incorrect supply voltage or water damage excessive dust build up in the fixture or internal fans which can cause overheating While under warranty ColorVerge Lighting pr...

Page 18: ...here are no user servicable parts in this fixture Do not attempt to open and repair this fixture Please refer to a ColorVerge Lighting authorized service technician for any other problem with your fix...

Reviews: