There are three tracks of information possible on a magnetic stripe. This option selects the tracks
that will be decoded (read). Note that the magnetic stripe reader must have the hardware configu-
ration (read head and circuits) for reading the specified tracks. If a single or dual track reader is used,
the heads must be positioned to read the tracks selected by this option. The default is Any Track.(All
tracks written on the card will be read).
Track Separator Selection
This option allows the user to select the character to be used to separate data decoded by a multi-
ple-track reader. The default value is CR.
Send Start/End Sentinel
The reader can send the Start/End sentinel for a track, decoded without error.
Send LRC in Card Data
The reader can send the track LRC for a properly decoded track.
For Track 2 only Send Account Number
The reader can only send account Number if it is true. And if it is false, the reader sends all
Track 2 data.
Send Error Indication
This option let reader to send out [SS]E[ES] if failed to read or missing data on a selected track. The
default is off.
The error output for track 1 is „%E?“.
The error output for track 2 is „;E?“.
The error output for track 3 is „+E?“.
Track Settings
Summary of Contents for Vion
Page 1: ...Errors excepted subject to change www colormetric net Vion User Manual Version 1 0...
Page 9: ...9 www colormetric net Colormetrics Vion 2 7 Internal Layout...
Page 23: ...23 www colormetric net Colormetrics Vion 3 Click Next 4 Select None Click Next 5 Click OK...
Page 25: ...25 www colormetric net Colormetrics Vion 9 Click Next 8 Click Next...
Page 44: ...44 www colormetric net Colormetrics Vion...